752400
20
Zoom out
Zoom in
Previous page
1/136
Next page
Page 20
For Accurate Application Sizing Consult CALOREX Heat Pumps Ltd.
NOTES:-
1) Weight and dimensions nett
2) Performance design Iimitations
Ambient = 7°C min, 40°C max
Water = 10°C min, 40°C max
3) Pool water to have correct balance, pH 7.4 ± 0.4 Free Chlorine 1.0 - 3.0 ppm
4) Allow 500mm clearance to service panels
5) Calorex reserve the right to change or modify models without prior notice.
6) R407c Global warming potential (GWP) 1700.
1mm WG = 9.8 Pa
1m hd = 1.4 psi
1L/min = 0.22 gall/min
HEAT PUMPS FOR OUTDOOR POOLS
SUMMER SEASON (AL, BL)
MODEL Units AW 629 AW 829
HEAT TO POOL WATER
AMBIENT 10°C, WATER 24°C kWhr 7.2 9.9
AMBIENT 20°C, WATER 24°C kWhr 9.2 12.5
ELECTRICITY
ELECTRICAL SUPPLY 1 PHASE
TOTAL POWER CONSUMED
AMBIENT 10°C, WATER 24°C kWhr 1.8 2.3
AMBIENT 20°C, WATER 24°C kWhr 2.0 2.5
MIN SUPPLY CAPACITY (Max F.L.A.) 1 ph N:- A 14.3 17.6
MAX SUPPLY FUSE 1 ph N:- A 20.0 25.0
WATER FLOWS ETC
POOL WATER FLOW RATE:- l/m n 115 115
POOL WATER PRESSURE DROP (@ Rated Flow):- m hd 1.1 1.1
MAX WORKING PRESSURE POOL WATER:- bar 3.5 3.5
POOL WATER CONNECTIONS:- inches 1 1/2" BSPM 1 1/2" BSPM
CONDENSATE DRAIN CONNECTIONS:- inches 3/4"BSPM STUD 3/4"BSPM STUD
COMPRESSOR
NOMINAL POWER CONSUMED kWhr 1.8 2.14
L.R.A. 1 ph N:- A 66 63
R.L.A. 1 ph N:- A 11.4 14
SOFT START AMPS 1 ph N:- A 29 28
MAIN FAN
AIR FLOW (Anemometer @ air on grille. Wet evaporator):- m³/hr 1800 2700
MAX EXTERNAL STATIC PRESSURE:- mm Wg 00
F.L.A. 1 ph N:- A 0.7 0.7
GENERAL DATA
HERMETIC SYSTEM
GAS CHARGE R407c kg 1.6 2.05
PHYSICAL DIMENSIONS
WIDTH (Unpacked):- mm 1049 1227
DEPTH (Unpacked):- mm 577 577
HEIGHT (Unpacked):- mm 787 787
WEIGHT (Unpacked):- kg ?? ??
230V/~1N/ 50Hz
DATA SHEET
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Calorex AW629 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Calorex AW629 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 1,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info