electrical requirements
ELECTRICAL
Your CALDERA spa has been carefully designed to give you maximum
safety against electrical shock. Connecting the spa to an improperly
wired circuit will negate many of the spa’s safety features. Improper
wiring may also cause electrocution, risk of fire, and other risks of
injuries. Please read and follow the electrical installation requirements
and instructions for your spa completely! Your spa must be supplied by
a residual current device (RCD) - with a tripping rating not exceeding 30
mA in an electrical subpanel.
VACANZA SPAS MUST BE WIRED IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. ALL
ELECTRICAL WORK SHOULD BE DONE BY AN EXPERIENCED,
LICENSED ELECTRICIAN. WE RECOMMEND THE USE OF
APPROPRIATE ELECTRICAL CONDUIT, FITTINGS, AND WIRE FOR
ALL CIRCUITS.
The MARINO, CAPITOLO, CELIO, VANTO and AVENTINE spas
require a 16 amp, single phase, 230 volt, three wire service (one line,
one neutral, one ground).
The AVENTINE can be converted to a 20 amp service allowing the
high speed jet pump to operate simultaneously with the heater. A
CALDERA Spa Technician must reconfigure spa using the soft jumpers
to allow the heater to run concurrent with jet pump.
The PALATINO spa requires a 20 amp single phase, 230 volt,
three wire service (one line, one neutral, one ground) found below.
Additionally, one main disconnect switch with at least 3 mm separation
between contacts must be used for all electrical circuits to the spa.
Mount the subpanel according to local codes, but not closer than 1.5
meters (5 feet) away.
CONDUIT INSTALLATION INSTRUCTIONS
1. To connect the electrical service, first remove the screws from the
equipment compartment door. Carefully pull the door panel down
and away in order to remove it completely from the spa.
2. Locate the control box. Loosen the screws on the front of the
control box. Remove the screws and the control box cover.
3. Route the electrical conduit through the access opening of the spa.
4. Connect the supply conduit to the control box and connect the
wiring as detailed below, or on the wiring diagram label on the
inside of the control box cover.
WARNING: Removing or bypassing any RCD breaker will result in an
unsafe spa and will void the spa’s warranty.
IMPORTANT: Should you ever find the need to move or relocate your
VACANZA spa, it is essential that you understand and apply these
installation requirements. Your VACANZA spa has been carefully
engineered to provide maximum safety against electric shock.
Remember, connecting the spa to an improperly wired circuit will negate
many of its safety features.
NOTE: Long wiring runs may require larger-gauge wire than stated.
230 VOLT 50HZ SUBPANEL WIRING
25A
16A
*20A *
* 20A ONLY
20A
6.0 mm2, Neutral, Blue
6.0 mm2, Ground, Grn/Ylw
6.0 mm2, Line, Brown
Less than 15 meters (50 ft.)
More than 1.5 meters (5 ft.)
Main Service
Electrical Panel
220-240 VAC
Single Pole Circuit
Breaker (Non
RCD)
Sub-Panel with
RCD breaker
Less than 30 meters (100 ft.)
Control Box
6.0 mm2, Neutral, Blue
6.0 mm2, Ground, Grn/Ylw
6.0 mm2, Line, Brown
12 Electrical
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Caldera Vacanza - serie 2022 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Caldera Vacanza - serie 2022 in the language / languages: English as an attachment in your email.

The manual is 3.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Caldera Vacanza - serie 2022

Caldera Vacanza - serie 2022 User Manual - German - 40 pages

Caldera Vacanza - serie 2022 User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info