809121
5
Zoom out
Zoom in
Previous page
1/24
Next page
ladders, water pipes, or other metal within
1.5 m of the spa to comply with local
requirements. The means of disconnection
must be readily accessible, but must be
installed at least 1.5 m from the spa.
Your spa requires a suitably rated circuit
breaker to open all ungrounded supply
conductors.
Your spa must have a ground fault circuit
interrupter in an electrical subpanel.
Before each use of the spa and with the
unit operating, push the TEST button on
the breaker. The switch should click over
to the “Trip” position. Wait 30 seconds
and reset the GFCI breaker by switching
it completely off and then completely
on. The switch should then stay on. If
the interrupter does not perform in this
manner, it is an indication of an electrical
malfunction and the possibility of an
electric shock. Disconnect the power until
the fault has been identified and corrected.
IMPORTANT: Failure to wait 30 seconds
before resetting the GFCI may cause
the spa’s Power Indicator (on the control
panel) to blink. If this occurs, repeat the
GFCI test procedure.
DANGER: RISK OF
ELECTRICAL SHOCK
Install spa at least 1.5 m from all metal
surfaces. A spa may be installed within
5 feet of a metal surface if each metal
surface is permanently connected by a
minimum 6 mm² solid copper conductor
attached to the wire ground connector on
the terminal box that is provided for this
purpose if in accordance with your national
electrical code.
Do not permit any electrical appliances,
such as a light, telephone, radio, or
television within 1.5 m of a spa. Failure
to maintain a safe distance may result in
death or serious personal injury due to
electrocution if the appliance should fall
into the spa.
Install your spa in such a way that
drainage is away from the electrical
compartment and from all electrical
components.
DO:
Be sure your spa is connected to the
power supply correctly - use a licensed
electrical contractor.
Disconnect the spa from the power supply
before draining the spa or servicing the
electrical components.
Test the Ground Fault Circuit Interrupter(s)
before each use.
DON’T:
Use the spa with the equipment
compartment door removed.
Place electrical appliances within 1.5 m of
the spa.
Use an extension cord to connect the spa
to its power source. The cord may not be
properly grounded and the connection is
a shock hazard. An extension cord may
cause a voltage drop, which will cause
overheating of the jet pump motor and
motor damage.
Attempt to open the electrical control box.
There are no user serviceable parts inside.
RISKS TO AVOID
DANGER: RISK OF INJURY
DO NOT sit in the filter compartment area.
Sitting in this area can cause:
a) Restriction of Filter Pump suction/
vacuum
b) Damage to components
Both can result in bodily harm. Should
damage occur to components in this area,
replace immediately!
To reduce the risk of injury to persons, DO
NOT remove floating weir, basket, and filter
located in the filter compartment while the
spa is running.
The suction fittings in the spa are sized to
match the specific water flow created by
SAFETY INFORMATION
2
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Caldera Fantasy Spa 2018 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Caldera Fantasy Spa 2018 in the language / languages: English as an attachment in your email.

The manual is 0.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Caldera Fantasy Spa 2018

Caldera Fantasy Spa 2018 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info