Fig. 46 - Ducting system example
If the stove is not tted with ducting system, it provide a hot air capacity ranging from a minimum of 60 m
3
/h
to a maximum of 130 m
3
/h with a temperature ranging between 90°C and 170°C.
For the ducting system, we recommend using a pipe with a maximum length of 6 mt and up to three 90°
elbows in order to maintain hot air temperature.
Use pipes with smooth internal surface and a diameter of 80 mm.
Fit the pipe with insulating material if it passes through a cold wall.
The outlet must be protected by a grid with wide mesh and a minimum total surface area of 40 cm
2
.
If the pipes used are longer than 6 mt, the air capacity ranges from a minimum of 58 m
3
/h to a maximum of
90 m
3
/h and the temperature from 65°C to 130°C. (These values refer to the laboratory used for the tests. The
room where the stove is installed may register different values both in terms of capacity and temperature).
If you wish to increase air capacity, install at the end of the pipe a small wall-mounted fan with a capacity
exceeding 130 m
3
/h. The installation must be carried out by an authorised technician.
According to the factory parameters, 1/2 of the generated heat is conveyed into the room where the stove
is installed, while the remaining 1/2 are conveyed through the left ducting pipe system.
Balance heat output with air capacity to obtain the best performance (see ). The operation above must be
carried out by an authorised technician.
11.14 STOVE CALIBRATION AND DEPRESSION MEASUREMENT
This stove has a pickup point positioned on the tank in order to measure the depression of the combustion
chamber and verify its proper operation.
To do this, proceed as follows:
Loosen nut "D" from the bottom of the stove, near the pressure switch (see Fig. 47 page 25.)
Connect a digital pressure switch with a tube to detect the negative pressure (see Fig. 48 page 25).
Load the feed screw via appropriate function.
Start the stove and set "Set_Flame" to power 1 (the start-up time of this stove lasts between 8 and 10 minutes
to ensure minimum draught).
Compare the read values with those on the table.
Change power every 10 minutes and wait for it to stabilise.
Access the user menu and, if necessary, change the parameters.
Fig. 47 - Casing removal Fig. 48 - Digital pressure switch connection
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel Wall3 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel Wall3 Plus in the language / languages: English as an attachment in your email.

The manual is 21,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel Wall3 Plus

Cadel Wall3 Plus User Manual - German - 48 pages

Cadel Wall3 Plus User Manual - Dutch - 48 pages

Cadel Wall3 Plus User Manual - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info