643762
11
Zoom out
Zoom in
Previous page
1/48
Next page
11
VEGA - SIRE
3
PLUS - DOGE
3
PLUS - SFERA
3
- SFERA
3
PLUS - PRINCE
3
- PRINCE
3
PLUS - GLOBE - TREND - ELISE
3
PLUS
EN
In some countries and/or regions the installation with sealed-chamber is obligatory: in case
of doubt, please follow the most restrictive regulations.
How to connect to the stove in the sealed chamber with concentric system:
Fig. 8 - Phase1 Fig. 9 - Phase 2 Fig. 10 - Phase 3
Original position with completely embedded tube (see Fig. 8 page 11).
Pull out the tube for 2 cm (see Fig. 9 page 11).
Insert the female tube ø 6 cm (see Fig. 10 page 11).
9.10 CHIMNEY FLUE CONNECTION
Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are
realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278.
All must be effected by specialized personnel or companies as provided by UNI 10683:2012.
The connection between the appliance and the chimney ue should be short in order to favor the draught
and to avoid condensation in the pipes.
The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm).
Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is
sealed with the plug given with standard equipment.
SYSTEM TYPE Ø80 mm PIPE Ø100 mm PIPE
Minimum vertical length 1,5 mt 2 mt
Maximum length (with 1 union) 6,5 mt 10 mt
Maximum length (with 3 unions) 4,5 mt 8 mt
Maximum number of unions 3 3
Level section (minimum inclination 3%) 2 mt 2 mt
Installation at a height above 1200 m a.s.l. NO Obligatory
Use a plate pipe for stoves of Ø80 mm or Ø100 mm depending on the type of system and with silicone gaskets.
It is forbidden to use metal, bre cement or aluminium exible pipes.
For change of direction it is obligatory always to use a union (with angle > 90°) with inspection plug which
enables an easy periodic cleaning of the pipes.
Please assure you that after the cleaning the inspection plugs are sealed with its efcient gasket.
It is forbidden to connect more appliances to the same fume conduit.
It is forbidden to convey in the same fume conduit exhausts from overhanging cooker hoods.
It is forbidden to exhaust ue gases directly from the wall towards the outside and closed spaces also at open top.
It is forbidden to connect any other appliance (wood stoves, cooker hoods, boilers, etc...).
The fume conduit must be placed at a distance of minimum 500 mm from ammable or heat-susceptible
components.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel TREND at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel TREND in the language / languages: English as an attachment in your email.

The manual is 19,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel TREND

Cadel TREND Usermanual and installation guide - German - 48 pages

Cadel TREND Usermanual and installation guide - Dutch - 48 pages

Cadel TREND Usermanual and installation guide - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info