IDROSTUFE
14
Scroll to “Settings” using the arrows
Press “menu to confirm.
Scroll to “Season” using the arrows.
Press “menu to confirm.
Select “Summer” or Winter” with the + - keys.
Press “menu to confirm and esc” to exit.
q - Technical menu
To access the technical menu one must contact an assistance centre as one needs a password to enter.
To intervene on the “technical menu act as follows:
Press the “menu button.
Scroll to “Settings” using the arrows
Press “menu to confirm.
Scroll to Technical menu” using the arrows.
Press “menu to confirm.
Select “Product Type”, “Service, “Parameters”, “DHW Parameters”, “Meters memories”, “Enable fan and “Puffer data with the
+ - keys.
Press “menu to confirm and esc” to exit
9.5 AUTO ECO MODE SEE SECTION FG
To activate the Auto Eco” mode and adjust the time refer see section f-g.
The possibility to adjust the “ECO shutdown t” comes from the need to ensure proper operation in the various rooms the boiler
can be installed in and prevent continuous shutdowns and start-ups in the event the temperature is subject to sudden changes (air
currents, poorly insulated rooms, etc.).
The ECO shutdown procedure is activated automatically when all the power demand devices involved in the system configu-
ration are satisfied: room probe/external thermostat, flow switch, puffer thermostat/ntc (10 k ß3435) or boiler thermostat/
ntc (10 k ß3435). If all devices present are satisfied the “ECO shutdown t time decrease starts (by default 10 minutes, it can
be changed within the “Settings menu”). During this stage the panel displays ON with a small flame and alternately Chrono (of
active) - Eco active. The minutes indicating the countdown for the Eco Stop are shown at the top of the display. The flame goes into
P1 and stays there until the programmed “Eco shutdown t” time has elapsed and if the conditions are still satisfied, it goes into the
shutdown stage. The ECO switch off countdown resets if one of the devices boosts power again.
When switch off starts the panel displays: Off - Eco Active - small flashing flame.
Once the boiler has reached the off condition, the panel displays OFF-ECO with the extinguished flame symbol.
To restart from ECO the following conditions must be satisfied simultaneously:
Power demand
After 5 minutes from the beginning of shutdown.
TH2O < TSetH2O.
If the domestic hot water (DHW) demands power - if envisaged - the first 5’ are ignored and the boiler restarts as needed.
NOTE: In configuration 4 - 5 the Auto Eco mode is enabled automatically. Even when one sets the summer function in configura-
tion 2 - 3 it is enabled automatically. In the cases where it is designed to be active, it is not possible to deactivate the mode.
9.6 PROGRAMMED MODE TIMER  MAIN MENU
Setting the current day and time is essential for the proper operation of the timer.
There are six TIMER programmes, for each one the user can decide the start-up and shutdown time as well as the day of the week
in which it is active. When one or more programmes are active, the panel alternately displays the boiler status and TIMERn
whereby n is the number relating to the activated timer programmes, separated from each other with a dash
Example:
TIMER 1 Timer programme 1 active.
TIMER 1-4 Timer programmes 1 and 4 active.
TIMER 1-2-3-4-5-6 Timer programmes all active.
EXAMPLE OF PROGRAMMING
With boiler on or off:
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel TESIS 16-23 AIRTIGHT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel TESIS 16-23 AIRTIGHT in the language / languages: English as an attachment in your email.

The manual is 2.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info