TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COMMISSION
REGULATIONS (EU) 2015/1185 - (EU) 2015/1186 (PRODUCT FICHE)
Manufacturer CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy
Trademak: model identier
CADEL: AQUOS3 16 -IDRO RIVER3 16- MAYA3 16- IDRO PRINCE3 16
FREEPOINT: TESIS 16 AT
PEGASO: MIRA 16
Description Pellet stove
Indirect heating functionality Yes
Direct heat output 3,3 kW
Indirect heat output 12,9 kW
CPR harmonised standard EN 14785
Notied body KIWA CERMET ITALIA S.P.A.(N.B.0476)
Preferred fuel (unique) Compressed wood with moisture content < 12 % YES
Wood logs with moisture content ≤ 25 % NO
Other woody biomass NO
ηs82 %
EEI 124 -
Energy Eciency Class (A++ to G scale) A+
Space heating emissions at nominal heat output
PM (al 13% O2)19 mg/Nm3
OGC (al 13% O2)2,2 mg/Nm3
CO (al 13% O2)74 mg/Nm3
NOx (al 13% O2)109 mg/Nm3
Space heating emissions at minimum heat output
Only required if correction factors F(2) or F(3) are applied
PM (al 13% O2)28 mg/Nm3
OGC (al 13% O2)7,7 mg/Nm3
CO (al 13% O2)138 mg/Nm3
NOx (al 13% O2)133 mg/Nm3
Heat output Nominal heat output (Pnom)16,2 kW
Minimum heat output (indicative) (Pmin)4,7 kW
Useful eciency (NCV as received) Useful eciency at nominal heat output (ηth,nom)93,3 %
Useful eciency at minimum heat output (indicative) (ηth,min)96,5 %
Auxiliary electricity consumption At nominal heat output (elmax)0,115 kW
At minimum heat output (elmin)0,060 kW
In standby mode (elsb)0,004 kW
Type of heat output/room temperature control (select one)
Single stage heat output, no room temperature control NO
Two or more manual stages, no room temperature control NO
With mechanic thermostat room temperature control NO
With electronic room temperature control NO
With electronic room temperature control plus day timer NO
With electronic room temperature control plus week timer YES
Other control options (multiple selections possible) Room temperature control, with presence detection NO
Room temperature control, with open window detection NO
With distance control option NO
Permanent pilot ame power requirement Pilot ame power requirement (if applicable) (Ppilot)N.A. kW
Observe the specic precautions for installation, assembly and maintenance indicated in the manual accompanying the product.
Issue date: 18.11.2021
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel TESIS 16-23 AIRTIGHT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel TESIS 16-23 AIRTIGHT in the language / languages: English as an attachment in your email.

The manual is 2.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info