815223
19
Zoom out
Zoom in
Previous page
1/36
Next page
new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
19
8.13 NOTES FOR TIMER OPERATION
Start-up with the timer always takes place with the last temperature and ventilation settings (or with default 20°C and V3
settings in the event they have never been changed).
It is possible to set the shutdown time from “ignition time + 10 minutes up to 23:50. If 24:00 is set as shutdown time, the stove
will not switch off (use this shutdown time, for example, when the next day is programmed to continue from 00:00).
If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00 of the next day:
the boiler stays on.
A programme proposes a start-up and shutdown in times included within another timer programme: if the boiler is already on,
start will not have any effect, while OFF will switch it off.
In the boiler on and timer active condition, press the OFF key and the boiler will switch off, it will switch on automatically at
the next time set on the timer.
In the boiler off and timer active condition, press the ON key and the boiler will switch on, it will switch off at the time set on
the active timer.
8.14 AUTO ECO MODE SEE SECTION FG
To activate the Auto Eco” mode and adjust the time refer see section f-g.
The possibility to adjust the “ECO shutdown t” comes from the need to ensure proper operation in the various rooms the boiler
can be installed in and prevent continuous shutdowns and start-ups in the event the temperature is subject to sudden changes (air
currents, poorly insulated rooms, etc.).
The ECO shutdown procedure is activated automatically when all the power demand devices involved in the system configu-
ration are satisfied: room probe/external thermostat, flow switch, puffer thermostat/ntc (10 k ß3435) or boiler thermostat/
ntc (10 k ß3435). If all devices present are satisfied the “ECO shutdown t time decrease starts (by default 10 minutes, it can
be changed within the “Settings menu”). During this stage the panel displays ON with a small flame and alternately Chrono (of
active) - Eco active. The minutes indicating the countdown for the Eco Stop are shown at the top of the display. The flame goes into
P1 and stays there until the programmed “Eco shutdown t” time has elapsed and if the conditions are still satisfied, it goes into the
shutdown stage. The ECO switch off countdown resets if one of the devices boosts power again.
When switch off starts the panel displays: Off - Eco Active - small flashing flame.
Once the boiler has reached the off condition, the panel displays OFF-ECO with the extinguished flame symbol.
To restart from ECO the following conditions must be satisfied simultaneously:
Power demand
After 5 minutes from the beginning of shutdown.
TH2O < TSetH2O.
If the domestic hot water (DHW) demands power - if envisaged - the first 5’ are ignored and the boiler restarts as needed.
NOTE: In configuration 4 - 5 the Auto Eco mode is enabled automatically. Even when one sets the summer” function in configura-
tion 2 - 3 it is enabled automatically. In the cases where it is designed to be active, it is not possible to deactivate the mode.
8.15 SLEEP FUNCTION MAIN MENU
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must
switch off.
To set the Sleep function act as follows:
Enter MENU
Scroll to SLEEP with the <> arrows
Press Menu
With the + - keys adjust the desired shutdown time.
The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day (I can therefore
delay the shutdown for up to a maximum of 23 hours and 50 minutes).
Fig. 12 - Sleep
If the SLEEP function is active with the TIMER active the first has priority over the latter, therefore the boiler will not switch off at
the time set on the timer but instead by the time established by the sleep function, even if later than the time set on the timer.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel TESIS 16-23 AIRTIGHT T2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel TESIS 16-23 AIRTIGHT T2 in the language / languages: English as an attachment in your email.

The manual is 1.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info