ALARM CAUSE SOLUTION INTERVENTION
AL 8 - FAILURE
DEPRESS
Obstructed exhaust
The exhaust chimney is partially or totally obstructed. Call
en expert stove-repairer who executes a check from the
exhaust up to the chimney pot.
Fume fan out of order
The pellet can burn also thanks to the chimney ue
depression without the aid of the fan. Have the fume fan
immediately replaced. It can be noxious to health to let
the stove running without fan.
Obstructed connecting
nozzle
Clean the connecting nozzle.
Faulty pressostat Replace the pressostat.
Faulty electronic board Replace the mother board.
Extreme chimney lenght
Contact an expert stove repairer and check that the
exhaust chimney is in compliance with regulations: see
CHIMNEY FLUE page 6.
Advers whether
conditions
In case of strong wind there can be a negative pressure
to the chimney. Check and switch the stove on again.
The re door is not
correctly closed
Close the re door correctly and check if the gaskets are
broken.
Fire door microswitch
faulty or out of order
Replace the re door microswitch.
15.2 PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty to
check if the parameters of the mother board correspond to those of the table you own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized
Technician on order to avoi irreparable damages!
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel SQUARE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel SQUARE in the language / languages: English as an attachment in your email.

The manual is 7,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel SQUARE

Cadel SQUARE Usermanual and installation guide - German - 40 pages

Cadel SQUARE Usermanual and installation guide - Dutch - 38 pages

Cadel SQUARE Usermanual and installation guide - French - 40 pages

Cadel SQUARE User Manual - Italian, Portuguese, Spanish - 354 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info