643389
10
Zoom out
Zoom in
Previous page
1/36
Next page
10
CLOE - CLOE
3
- SQUARE
EN
LEGEND Fig. 6 page 9
1 Room to ventilate
2 External air inlet
The room must be endowed with an external air recycling for a good climate in your ambient.
The air inow from outside to the inner occurs directly, through an opening on the external wall of the room
(see Fig. 6 page 9).
Bedrooms, garages, and store of ammable materials are excluded.
The air inlet should have a total net surface of 80 sqcm
2
: the aforesaid surface is to widen if inside the room
there are other activated appliances (for example: electric ventilators for foul air suction, cooker hoods, other
stoves, etc...) which depress the environment.
At switched on appliance it is necessary to check that the pressure fall between the room and the outside
does not exceed 4,0 Pa value: if necessary widen the air inlet (EN 13384).
The air inlet must be realized at a height close to the oor with an external grid against birds. In such a way it
cannot be obstructed by any object.
In case of installation with sealed-chamber the air inlet is not necessary.
9.9 COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATION
Fig. 7 - Air inlet for sealed-chamber installation
LEGEND Fig. 7 page 10
1 ≥ 1,5 mt
2 ≥ 0,3 mt
3-3 Sectional view
4 Shield grid
5 Curve inlet to turn downwards
Check FEATURES page 35 if the purchased stove has a sealed-chamber. If the stove is endowed with a sealed-
chamber and you want also the whole installation with sealed chamber, please read the following instructions:
It is necessary to extract the air for combustion directly from outside.
Use a tube with minimum Ø60 mm and maximum 2 meters lenght; to connect see the back of the stove.
French standards require installation in double-walled ues (concentric system). The combustion air is drawn
from the cavity.
During installation step is necessary to verify the minimum distances required for the combustible air inlet as
(for example) an open door or window causes a vortex which could remove the combustible air necessary
to the stove (see the underlying scheme).
On the external wall it is necessary to install a curve at 90° to protect the combustible air inow from wind
effects: turn the curve inlet downwards, see Fig. 7 page 10.
Endow the curve with an external shield grid against birds in such a way that it cannot be obstructed by any
object.
Check with your local authorities if exists any restrictive regulation regarding the combustible
air inlet: if present, they must be applied
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel SQUARE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel SQUARE in the language / languages: English as an attachment in your email.

The manual is 7,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel SQUARE

Cadel SQUARE Usermanual and installation guide - German - 40 pages

Cadel SQUARE Usermanual and installation guide - Dutch - 38 pages

Cadel SQUARE Usermanual and installation guide - French - 40 pages

Cadel SQUARE User Manual - Italian, Portuguese, Spanish - 354 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info