new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
13
h - Pump on T (default 50°C).
i - Auxiliary boiler (default deactivated).
j - Pellet recipe.
k - Smoke rpm % ventilation.
l - Maximum power (1-5 - default 5).
m - Components test (displayed only when the boiler is switched off)
n - “Chimney sweep function (activated only when the boiler is switched on, for field emissions test).
o - System configuration.
p - Season.
q - Technical menu.
NOTE: Some of the items listed above cannot be activated in certain system configurations”.
a - Language
To select the language act as follows:
Press the menu button.
Scroll to “Settings” using the arrows
Press menu to confirm.
Scroll to “language” using the arrows.
Press menu to confirm.
With the + - keys select the language of interest (IT/EN/DE/FR/ES/NL/PL/DA)
Press menu to confirm and esc” to exit.
b - Cleaning
To select “Cleaning (only when the boiler is switched off) act as follows:
Press the menu button.
Scroll to “Settings” using the arrows
Press menu to confirm.
Scroll to “Cleaning using the arrows.
Press menu to confirm.
Select “On” with the + - keys.
Press menu to confirm and esc” to exit.
c - Feed screw loading
Allows to fill the pellets loading system. It can only be activated with the boiler switched off, it displays an 180” countdown after
which the feed screw stops automatically, as when exiting the menu.
To select “Feed screw loading (only when the boiler is switched off) act as follows:
Press the menu button.
Scroll to “Settings” using the arrows
Press menu to confirm.
Scroll to “Feed screw loading using the arrows.
Press menu to confirm.
Select “Enable” with the + - keys.
Press menu to confirm and esc” to exit.
d - Tones
This function is disabled by default, so to enable act as follows:
Press the menu button.
Scroll to “Settings” using the arrows
Press menu to confirm.
Scroll to “tones” using the arrows.
Press menu to confirm.
Select “On” with the + - keys.
Press menu to confirm and esc” to exit.
e - External thermostat (see relative chapter)
EXTERNAL THERMOSTAT (not included with the boiler, it is the users responsibility)
The stove can also be temperature-controlled by an external room thermostat. It is positioned centrally with respect to the room
where the appliance is installed and ensures greater consistency between the heating temperature requested of the stove and the
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel RIVERIDRO 16 T2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel RIVERIDRO 16 T2 in the language / languages: English as an attachment in your email.

The manual is 1.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel RIVERIDRO 16 T2

Cadel RIVERIDRO 16 T2 User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info