815230
23
Zoom out
Zoom in
Previous page
1/40
Next page
23
RIVER IDROTECH 18 - 24 - 24H2O
Fig. 16 - Door open Fig. 17 - deteriorated gasket Fig. 18 - Timer: 90 seconds
To operate correctly, the stove must work with the pellet hopper door always closed; should it remain open for
more than 90 seconds, the stove switches off.
The loading system stops when the tank door is opened.
Before closing the lid, make sure there are no pellets below the gasket. Pellets deteriorate the gasket and
eliminate its airtight sealing. (vedi Fig. 17)
10 SAFETY DEVICES AND ALARMS
The product is supplied with the following safety devices
10.1 PRESSURE SWITCH
It controls pressure in the fume duct. It blocks the pellet feed screw in the following instances:
clogged exhaust
Significant negative (wind)
clogged fume passages
open pellet loading tank
open fire door or worn/broken gaskets.
see SMOKE RPM VARIATION User Manual
10.2 SMOKE TEMPERATURE PROBE
Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature drops below the
preset value.
10.3 CONTACT THERMOSTAT IN THE FUEL HOPPER
If the temperature exceeds the preset safety level, it immediately shuts down boiler operation.
10.4 ELECTRICAL SAFETY
The product is protected against sudden current surges by a main fuse in the power supply panel on the rear part of the product.
Other fuses that protect the electronic boards are found on the latter.
10.5 SMOKE FAN
If the fan stops, the electronic board promptly shuts off the pellets supply and an alarm message is displayed.
10.6 GEAR MOTOR
If the gear motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until a minimum level of
cooling is reached.
10.7 TEMPORARY POWER CUT
If the power cut lasts less than 10” the boiler returns to its previous operating status; if it lasts more it carries out a cooling/restart
cycle.
10.8 FAILED STARTUP
If during ignition no flame develops, the boiler will go into alarm condition.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel RIVER IDROTECH 24 H2O at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel RIVER IDROTECH 24 H2O in the language / languages: English as an attachment in your email.

The manual is 0.67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel RIVER IDROTECH 24 H2O

Cadel RIVER IDROTECH 24 H2O User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info