12.10 FUME TEMPERATURE
To check the fume temperature at the exhaust it is sufcient to keep pressed P2 key.
12.11 SWITCHING OFF
To switch the stove off, keep pressed P4 key: the display shows "FINAL CLEANING". After about 10 minutes, also the
fume fan switches off (this happens always, independently if the stove is hot or cold). Then "OFF" will be shown.
12.12 CLOCK SETTING
Press P3 key and then P5 key till underlining "SET CLOCK" menu (02).
Press once P3 (DAY) and with P1 and P2 keys select the day of the week (Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday, Sunday).
Press for the second time P3 key (HOURS) and with P1 and P2 keys set the hour.
Press for the third time P3 key (MINUTES) and with P1 and P2 keys select the minutes. Press for the fourth time
P3 key (DAY) and with P1 and P2 keys select the day of the month (1,2,3...29,30,31).
Press for the fth time P3 key (MONTH) and with P1 and P2 keys select the month:
Press for the sixth time P3 key (YEAR) and with P1 and P2 keys select the year.
To exit from the programme press P4 twice.
12.13 DAILY PROGRAMMING
It allows to enable, disable and settle the daily chronothermostat functions.
Press P3 key and then P5 key till the menu "SET CHRONO". Press once P3 key and with P5 and P6 keys select the
"PROGRAM DAY". Press once P3 till nding "CHRONO DAY". With P1 and P2 keys put in "OFF" or "ON". It is possible
to set two working times delimited by the set times.
After "CHRONO DAY":
Press P5: the display shows "START 1", with P1 and P2 keys set the ignition time value or put in "OFF".
Press P5: the display shows "STOP 1", with P1 and P2 keys set the switching off time value or put in "OFF".
Press P5: the display shows "START 2", with P1 and P2 keys set the ignition time value or put in "OFF".
Press P5: the display shows "STOP 2", with P1 and P2 keys set the switching off time value or put in "OFF".
Press P4 key three times to exit from the menu.
12.14 WEEKEND PROGRAMMING
It allows to enable, disable and settle the chronothermostat functions during saturday and sunday.
Press P3 key and then P5 key till the menu "SET CHRONO". Press once P3 key and with P5 and P6 keys select
"PROGRAM WEEKEND". Press once P3 till nding "CHRONO WEEKEND". With P1 and P2 keys put in "OFF" or "ON".
It is possible to set two working times delimited by the set times and valid only for saturday and sunday.
After "CHRONO WEEKEND":
Press P5: the display shows "START 1 WEEKEND", with P1 and P2 keys set the ignition time value or put in "OFF".
Press P5: the display shows "STOP 1 WEEKEND", with P1 and P2 keys set the switching off time value or put in
"OFF".
Press P5: the display shows "START 2 WEEKEND", with P1 and P2 keys set the ignition time value or put in "OFF".
Press P5: the display shows "STOP 2 WEEKEND", with P1 and P2 keys set the switching off time value or put in
"OFF".
Press P4 key three times to exit from the menu.
12.15 WEEKLY PROGRAMMING
It allows to enable, disable and settle the weekly hermostat functions (saturday and sunday included).
Press P3 key and then P5 key till the menu "SET CHRONO". Press once P3 key and with P5 and P6 keys select
"PROGRAM WEEK". Press once P3 till nding "WEEKLY CHRONO". With P1 and P2 keys put in "OFF" or "ON". It is
possible to set four working times delimited by the set times.
After "WEEKLY CHRONO":
Press P5: the display shows "START PROG-1", with P1 and P2 keys insert the ignition time value or put in "OFF".
Press P5: the display shows "STOP PROG-1", with P1 and P2 insert the switching off value or put in "OFF".
Press P5: the display shows "MONDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
Press P5: the display shows "TUESDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
Press P5: the display shows "WEDNESDA PROG-1", with P1 and P2 keys set "ON" or "OFF"".
Press P5: the display shows "THURSDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
Press P5: the display shows "FRIDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
Press P5: the display shows "SATURDAY PROG-1", with P1 and P2 keys set "ON" or "OFF"".
Press P5: the display shows "SUNDAY PROG-1", with P1 and P2 keys set "ON" or "OFF".
Now press P5 and repeat all the previous instructions for Prog-2, Prog-3, Prog-4.
To exit press three times P4.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel Miriam at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel Miriam in the language / languages: English as an attachment in your email.

The manual is 12,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel Miriam

Cadel Miriam User Manual - German - 40 pages

Cadel Miriam User Manual - Dutch - 40 pages

Cadel Miriam User Manual - French - 44 pages

Cadel Miriam User Manual - Italian - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info