Attention! When cleaning is completed, remember to put part “C”, brazier “B” and ash pan “D” back in place
and close all the doors (“G, “H”, “F”)back up again.
11.6 FUME PIPES ANNUAL CLEANING
Clean annually from soot with brushes.
The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney
flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This
operation must be executed at least once a year.
11.7 GENERAL CLEANING
For cleaning external and inner parts of the stove do not use steel wools, muriatic acid or other corrosive and abrasive materials.
11.8 CLEANING OF PAINTED METAL PANELS
To clean painted metal panels use a soft cloth. Do not use degreasant agents like alcool, diluents, acetone, gasoline because these
could irremediably damage the varnish.
11.9 CLEANING OF CERAMIC AND STONE PANELS
Some stove models has an external lining made up of ceramic or stone. These pieces are handmade therefore they could inevitably
present crazings, seedinesses, shadings.
To clean ceramic or stone panels use a soft and dry cloth. If using any cleaners this will seep through the crazings putting them in
evidence.
11.10 GASKET REPLACEMENT
In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in
order to guarantee the good running of the stove.
Use exclusively original spare parts.
11.11 GLASS CLEANING
The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks.
The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explosions.
You should clean the fire door glass every day!
11.12 CLEANING THE EXCHANGER AND THE COMPARTMENT UNDER THE BRAZIER EVERY 2/3 DAYS
Cleaning the exchanger and the compartment under the brazier is a simple task but very important to always maintain the decla-
red performance.
As such, we recommend cleaning the internal exchanger every 2-3 days, following these simple tasks in order:
Activate “CLEANING” function - when the boiler is off, press - menu, select “Settings”, use the <> arrows to select “Clea-
ning”, confirm with “Menu”, active cleaning ON” using the +- keys. This procedure activates the smoke extraction fan to the
maximum, in order to expel the soot that is stirred up while cleaning the exchanger.
Clean the pipe unit - Using lever A, located under the tank cover, vigorously shake the turbulators 5-6 times. This removes
the soot deposited on the exchanger smoke ducts during normal boiler operation.
Disable the CLEANING” function - this function is automatically disabled after two minutes. If you need to stop this fun-
ction sooner, press the “Esc key.
Clean the smoke conveyor compartment(fig. on next page)
The boiler is equipped with a removable ash drawer to collect any soot and ash build-up (previous page).
Once cleaning is complete, close the cover and ash drawer.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel MIRA 22 T2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel MIRA 22 T2 in the language / languages: English as an attachment in your email.

The manual is 1.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel MIRA 22 T2

Cadel MIRA 22 T2 User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info