14 TECHNICAL DOCUMENTATION FOR LOCAL SPACE HEATERS ACCORDING TO COM
MISSION REGULATIONS EU 2015/1185  EU 2015/1186 PRODUCT FICHE
Manufacturer CADEL srl - Via Foresto Sud 7 - 31025 Santa Lucia di Piave (TV) - Italy
Trademak: model identifier CADEL: RIVER IDRO 23 T2 - RIVER IDRO 23 H2O T2 - MAYA IDRO 24 T2
FREEPOINT: TESIS 23 AIRTIGHT T2
PEGASO:
Description Pellet stove
Indirect heating functionality Yes
Direct heat output 4,4 kW
Indirect heat output 18 kW
CPR harmonised standard EN 14785
Notified body KIWA CERMET ITALIA S.P.A.(N.B.0476)
Preferred fuel (unique) Compressed wood with moisture content < 12 % YES
Wood logs with moisture content ≤ 25 % NO
Other woody biomass NO
ηs88 %
EEI 130 -
Energy Efficiency Class (A++ to G scale) A++
Space heating emissions at nominal heat output
PM (al 13% O2)14 mg/Nm3
OGC (al 13% O2)2mg/Nm3
CO (al 13% O2)136 mg/Nm3
NOx (al 13% O2)99 mg/Nm3
Space heating emissions at minimum heat output
Only required if correction factors F(2) or F(3) are applied
PM (al 13% O2)18 mg/Nm3
OGC (al 13% O2)3mg/Nm3
CO (al 13% O2)150 mg/Nm3
NOx (al 13% O2)94 mg/Nm3
Heat output Nominal heat output (Pnom)22,4 kW
Minimum heat output (indicative) (Pmin)4,9 kW
Useful efficiency (NCV as received) Useful efficiency at nominal heat output (ηth,nom)92 %
Useful efficiency at minimum heat output (indicative)
th,min)96,7 %
Auxiliary electricity consumption At nominal heat output (elmax)0,117 kW
At minimum heat output (elmin)0,076 kW
In standby mode (elsb)0,002 kW
Type of heat output/room temperature control (select
one)
Single stage heat output, no room temperature control NO
Two or more manual stages, no room temperature
control NO
With mechanic thermostat room temperature control NO
With electronic room temperature control NO
With electronic room temperature control plus day
timer NO
With electronic room temperature control plus week
timer YES
Other control options (multiple selections possible)
Room temperature control, with presence detection NO
Room temperature control, with open window detec-
tion NO
With distance control option YES
Permanent pilot flame power requirement Pilot flame power requirement (if applicable) (Ppilot)N.A. kW
Observe the specific precautions for installation, assembly and maintenance indicated in the manual accompanying the
product.
Issue date: 13.09.2022
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel MAYA IDRO 16 T2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel MAYA IDRO 16 T2 in the language / languages: English as an attachment in your email.

The manual is 1.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel MAYA IDRO 16 T2

Cadel MAYA IDRO 16 T2 User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info