WALL
3
PLUS - LEAN
3
PLUS - MOON - TILE
3
PLUS
EN
Fig. 8 - Cut- Removal Fig. 9 - Connections
How to connect to the stove in the sealed chamber with concentric system:
Insert the N tting into the I air intake pipe (see Fig. 10 page 11 and Fig. 11 page 11). Connect N to Q
using a exible tube which can resist a temperature of 100°C (a exible aluminium tube is recommended).
Maximum height for the installation of a vertical exhaust ue (roof) HV = 6 mt (see Fig. 12 page 11).
Maximum height for the installation of a horizontal exhaust ue (wall) HO = 2.6 mt (see Fig. 12 page 11).
Fig. 10 - Flexible tube Fig. 11 - Connections Fig. 12 - Flue connections
LEGEND Fig. 10 page 11 - Fig. 11 page 11 - Fig. 12 page 11
I Combustion air intake with a diameter of 40 mm
N Rubber tting with a diameter of 40/60 mm
R Flexible aluminium tube
Q Coaxial pipe air combustion connection
Y Coaxial pipe air combustion intake
HO Height of coaxial ue with wall/horizontal exhaust
HV Height of coaxial ue with roof/vertical exhaust
9.10 CHIMNEY FLUE CONNECTION
Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are
realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278.
All must be effected by specialized personnel or companies as provided by UNI 10683:2012.
The connection between the appliance and the chimney ue should be short in order to favor the draught
and to avoid condensation in the pipes.
The fume conduit should be equivalent or longer than the outlet joint ones (Ø 80 mm).
Some stove models are endowed with a lateral and/or back exhaust. Check that the unused exhaust is
sealed with the plug given with standard equipment.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel Lean3 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel Lean3 Plus in the language / languages: English as an attachment in your email.

The manual is 21,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel Lean3 Plus

Cadel Lean3 Plus User Manual - German - 48 pages

Cadel Lean3 Plus User Manual - Dutch - 48 pages

Cadel Lean3 Plus User Manual - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info