8.11 PROGRAMMED MODE TIMER  MAIN MENU
Setting the current day and time is essential for the proper operation of the timer.
There are six TIMER programmes, for each one the user can decide the start-up and shutdown time as well as the day of the week
in which it is active.
When one or more programmes are active, the panel alternately displays the boiler status and TIMER n” whereby “n is the number
relating to the activated timer programmes, separated from each other with a dash
Example:
TIMER 1 Timer programme 1 active.
TIMER 1-4 Timer programmes 1 and 4 active.
TIMER 1-2-3-4-5-6 Timer programmes all active.
EXAMPLE OF PROGRAMMING
With boiler on or off:
access the MENU,
scroll to TIMER with the <> arrows,
press the “Menu” key
the system proposes “P1” (Press the <> keys for the subsequent timers P2,P3, P4, P5, P6)
to activate “P1” press the “Menu” key
press + - and select “ON”
confirm with the “Menu key
At this point it will propose 00:00 as starting time, with key + - adjust the starting time and press the “menu key to confirm.
The next step proposes a shutdown time of 10 minutes above that set for start-up: press the + key and adjust the shutdown time,
confirm with the “menu key.
Subsequently the system proposes the days of the week in which to activate or deactivate the previously set timer. With the - or +
key highlight with the white background the day in which one wishes to activate the timer and confirm with the menu” key. If no
day of the week is confirmed as active, in turn the timer programme will not appear active in the status screen.
Continue to program the following days or press “ESC to exit. Repeat the procedure to program the other timers.
8.12 PROGRAMMING EXAMPLES:
P1 P2
on off day on off day
08:00 12:00 mon 11:00 14:00 mon
Boiler on from 08:00 to 14:00
on off day on off day
08:00 11:00 mon 11:00 14:00 mon
Boiler on from 08:00 to 14:00
on off day on off day
17:00 24:00 mon 00:00 06:00 tue
Boiler on from 17:00 on monday to 06:00 on tuesday
8.13 NOTES FOR TIMER OPERATION
Start-up with the timer always takes place with the last temperature and ventilation settings (or with default 20°C and V3
settings in the event they have never been changed).
It is possible to set the shutdown time from “ignition time + 10 minutes” up to 23:50. If 24:00 is set as shutdown time, the stove
will not switch off (use this shutdown time, for example, when the next day is programmed to continue from 00:00).
If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00 of the next day:
the boiler stays on.
A programme proposes a start-up and shutdown in times included within another timer programme: if the boiler is already on,
start will not have any effect, while OFF will switch it off.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel INDACO 11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel INDACO 11 in the language / languages: English as an attachment in your email.

The manual is 0.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel INDACO 11

Cadel INDACO 11 User Manual - German - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info