643498
52
Zoom out
Zoom in
Previous page
1/56
Next page
52
AQUOS - IBIS - IDRON
EN
ANOMALY POSSIBLE CAUSES SOLUTIONS
In the automatic position the stove
always runs at full power.
Thermostat is set to minimum. Set the thermostat temperature again.
The room thermostat is in the maximum
position.
Set the thermostat temperature again.
Faulty temperature probe.
Check the probe and replace it, if
necessary.
Faulty or malfunctioning control panel.
Check the panel and replace it, if
necessary.
The product does not start.
No power supply.
Check that the plug is inserted and the
main switch is in the “I” position.
Pellet temperature probe triggered. Check recipe parameters.
Blown fuse. Replace the fuse.
Pressure switch broken (lockout
indicated).
Water pressure low in stove.
Water temperature probe triggered. Contact the service centre.
Clogged smoke exhaust or smoke duct.
Clean the smoke exhaust and/or the
smoke duct.
No increase in temperature with stove
in operation.
Incorrect combustion adjustment. Check recipe.
Boiler/system dirty. Check and clean the boiler.
Insufcient stove power.
Check that the stove is properly sized
for the requirements of the system.
Poor pellets quality. Use of manufacturer pellets.
Condensation in boiler.
Incorrect temperature setting. Set the stove to a higher temperature.
Insufcient fuel consumption. Check recipe.
Radiators cold in winter.
Room thermostat (local or remote) set
too low. If remote thermostat, check if
it is defective.
Set it at a higher temperature or
replace it (if remote).
Circulator does not run because
blocked.
Free up the circulator by removing
the plug and turning the shaft with a
screwdriver.
Circulator does not run.
Check the electrical connections of
the circulator; replace if necessary.
Radiators have air in them. Bleed the radiators.
High temperature variability of
domestic water.
Water ow rate too low.
Increase the water ow rate (minimum
3 litres per minute).
Little domestic hot water is provided.
Insufcient mains water pressure.
Check the calibration of the pressure
reducer valve.
Tap or mixer clogged with limescale. Install an autoclave.
Water unit clogged. Check and clean.
Clean or replace the plate heat
exchanger.
Hot water is not provided. Circulator (pump) blocked. Free the circulator (pump).
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel Idron 22 H2O at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel Idron 22 H2O in the language / languages: English as an attachment in your email.

The manual is 6,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel Idron 22 H2O

Cadel Idron 22 H2O Usermanual and installation guide - German - 56 pages

Cadel Idron 22 H2O Usermanual and installation guide - Dutch - 56 pages

Cadel Idron 22 H2O Usermanual and installation guide - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info