PANEL ALERT TYPE OF PROBLEM SOLUTION
A19 Water probe faulty.
Water probe disconnected / interrupted / defective /
not recognised.
A20 Puffer probe alarm.
Puffer probe disconnected / interrupted / defective /
not recognised.
A21 Triac alarm
The triac of the electronic card has stalled. Replace the
card.
SERVICE
Routine maintenance alert (it does not block
the system).
When this flashing message appears upon start-up, it
means that the preset operating hours have elapsed
before maintenance. Contact the service centre.
12.15 ALARM RESET
NEVER open the stove door while it is starting up initially or switching off, as the pellets are
still burning at this point and there may be volatile substances.
ATTENTION!
If smoke flows into the room from the appliance or the flue during operation or initial igni-
tion, switch off the device, air out the room, and immediately contact the installation/custo-
mer service technician.
To reset the alarm, you must hold down key 1 (ESC) for a few seconds. The stove performs a check to determine whether what
caused the alarm is still present.
If this is the case, the alarm will be shown again, otherwise the stove will switch OFF.
If the alarm persists, contact a service centre.
12.16 NORMAL SHUTDOWN ON THE PANEL: OFF WITH FLASHING FLAME
If the shutdown key is pressed or if there is an alarm signal, the boiler goes into the thermal shutdown phase which entails the
automatic execution of the following stages:
It stops pellets loading
The room fan (if provided) maintains the set speed until the smoke T reaches 100°C, then it automatically sets itself at the
minimum speed until it reaches the shutdown temperature
The smoke fan sets itself at maximum speed and maintains it for a fixed time of 10 minutes, at the end of which if the smoke
T has fallen below the shutdown threshold it switches off permanently, otherwise it sets itself at the minimum speed until it
reaches such threshold before switching off.
If the boiler was shutdown regularly but, due to thermal inertia the smoke temperature exceeds the threshold again, the
shutdown stage restarts at the minimum speed until the temperature goes down.
12.17 BLACKOUT WITH THE BOILER ON
In the event of a power cut (BLACKOUT) the boiler behaves as follows:
Blackout below 10”: it returns to its operation in progress;
In the event of a power cut that lasts over 10” with the boiler on or in the start-up stage, when the boiler is powered again it
goes back to the previous operating condition with the following procedure:
1) It cools down activating the smoke extractor at minimum power for 10’ and goes onto the next point;
1) It takes the boiler back to the operating condition before the blackout.
During stage 1 the panel displays ON BLACK OUT.
During stage 2 the panel displays Start-up.
If during stage 1 the boiler receives commands from the panel and thus carried out manually by the user, then the boiler stops
executing the blackout recovery status and proceeds to restart or shutdown as requested by the command.
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel IDRON 22 AIRTIGHT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel IDRON 22 AIRTIGHT in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel IDRON 22 AIRTIGHT

Cadel IDRON 22 AIRTIGHT User Manual - German - 76 pages

Cadel IDRON 22 AIRTIGHT User Manual - Dutch - 72 pages

Cadel IDRON 22 AIRTIGHT User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info