696857
49
Zoom out
Zoom in
Previous page
1/72
Next page
IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 -
TESIS 16-23
AIRTIGHT - HIDROFIRE 22.8
49
When switch off starts the panel displays: Off - Eco Active - small flashing flame.
Once the boiler has reached the off condition, the panel displays OFF-ECO with the extinguished flame symbol.
To restart from ECO the following conditions must be satisfied simultaneously:
Power demand
After 5 minutes from the beginning of shutdown.
TH2O < TSetH2O.
If the domestic hot water (DHW) demands power - if envisaged - the first 5’ are ignored and the boiler restarts as needed.
NOTE: In configuration 4 - 5 the Auto Eco mode is enabled automatically. Even when one sets the “summer” function in configura-
tion 2 - 3 it is enabled automatically. In the cases where it is designed to be active, it is not possible to deactivate the mode.
11.7 SYSTEM CONFIGURATION
Upon installation, the product must be set according to the type of system, selecting the appropriate parameter in the “SETTINGS” menu.
The possible configurations are 5, as described below:
CONFIGURATION DESCRIPTION
1
Room temperature management via probe on the stove or by enabling an external room thermo-
stat.
2
2.1 Room temperature management via probe on the stove or by enabling an external room
thermostat: instantaneous DHW production with plate exchanger.
2.2 Room temperature management via probe on the stove or by enabling an external room
thermostat; DHW production for boiler or storage tank with thermostat (optional).
DISCONNECT ANY 3-WAY VALVES AND INTERNAL FLOW SWITCHES
3
Room temperature management via probe on the stove or by enabling an external room thermo-
stat; boiler DHW production with ntc probe (10 k ß3435).
DISCONNECT ANY 3-WAY VALVES AND INTERNAL FLOW SWITCHES
4 External Puffer management controlled by thermostat.
5 External Puffer management controlled by ntc probe (10 k ß3435).
11.8 SYSTEM WITH: DIRECT VENT PELLET STOVE AND ROOM PROBE
Settable settings :
SETTING VALUES
ROOM TEMP. 5°C - 35°C
WATER TEMP. 30°C - 80°C
Parameters to set :
SETTING VALUES
Configuration 1
Hydraulic diagram :
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel IDRO PRINCE 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel IDRO PRINCE 30 in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel IDRO PRINCE 30

Cadel IDRO PRINCE 30 User Manual - German - 76 pages

Cadel IDRO PRINCE 30 User Manual - Dutch - 72 pages

Cadel IDRO PRINCE 30 User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info