11.2 NOTES FOR TIMER OPERATION
Start-up with the timer always takes place with the last temperature and ventilation settings (or with default 20°C and V3
settings in the event they have never been changed).
Start-up time ranges from 00:00 a 23:50
If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00 of the next day:
the boiler stays on.
A programme proposes a start-up and shutdown in times included within another timer programme: if the boiler is already on,
start will not have any effect, while OFF will switch it off.
In the boiler on and timer active condition, press the OFF key and the boiler will switch off, it will switch on automatically at
the next time set on the timer.
In the boiler off and timer active condition, press the ON key and the boiler will switch on, it will switch off at the time set on
the active timer.
11.3 SLEEP FUNCTION MAIN MENU
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must
switch off.
To set the Sleep function act as follows:
Enter MENU
Scroll to SLEEP with the <> arrows
Press Menu
With the + - keys adjust the desired shutdown time.
The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day (I can therefore
delay the shutdown for up to a maximum of 23 hours and 50 minutes).
If the SLEEP function is active with the TIMER active the first has priority over the latter, therefore the boiler will not switch off at
the time set on the timer but instead by the time established by the sleep function, even if later than the time set on the timer.
11.4 ADJUSTMENTS MENU
To access the adjustments menu act as follows:
Press the + - keys
Scroll with the <> arrows and select “Set Room T” or “Set Water T” or “Exchanger Speed”
Press menu to access the selected option.
Modify with the + - keys.
Press menu to confirm and esc to exit.
11.5 SETTINGS MENU
The SETTINGS menu allows to act on the boiler operating mode:
A. Language.
B. Cleaning (displayed only when the boiler is switched off).
C. Feed screw loading (displayed only when the boiler is switched off).
D. Tones.
E. External thermostat (activation).
F. Auto Eco (activation).
G. Eco-Shutdown T (default 10 minutes).
H. Pump on T (default 50°C).
I. Auxiliary boiler (default deactivated).
J. Pellet recipe.
K. Smoke rpm % ventilation.
L. Maximum power (1-5 - default 5).
M. Components test (displayed only when the boiler is switched off)
N. Chimney sweep function (activated only when the boiler is switched on, for field emissions test).
O. System configuration.
P. Season.
Q. Technical menu.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel IDRO PRINCE 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel IDRO PRINCE 30 in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel IDRO PRINCE 30

Cadel IDRO PRINCE 30 User Manual - German - 76 pages

Cadel IDRO PRINCE 30 User Manual - Dutch - 72 pages

Cadel IDRO PRINCE 30 User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info