3.8 SIZING
The vacuum (draft) of a flue also depends on its height. Check vacuum with the values shown in the technical features. Minimum
flue height is 3.5 metres.
The flue internal cross-section can be circular (best case), square, or rectangular (the ratio between the inner sides must be ≤1.5)
with the sides coupled with a 20mm minimum radius. Minimum cross-section must be Ø100mm.
The sections/lengths of the chimneys must, in any case, be properly sized according to the general calculation method used in UNI
EN13384-1 or other methods that have proven efficient.
Below are some examples of flues available on the market:
VERY GOOD GOOD POOR VERY POOR
AISI 316 steel chimney with
insulated twin walls with
ceramic fibre or equivalent
resistant to 400°C.
Refractory chimney with
insulated twin walls and
external sleeve in lightweight
concrete with honeycomb
materials, like clay.
Traditional clay square section
chimney with hollow insula-
ting inserts.
Avoid chimneys with rectan-
gular inner section in which
the ratio between the longer
side and the shorter side is
greater than 1.5 (for example,
20x40 or 15x30).
3.9 MAINTENANCE
Flues must always be clean, as build-ups of soot or unburnt oil reduce the cross-section, blocking draft, compromising proper stove
operation, and, in large amounts, can catch fire. Have the flue and chimney cap checked and cleaned by a qualified chimney sweep
at least once a year and, after the check/service, have them issue an undersigned report that the system is safe.
Failure to clean compromises system safety.
3.10 CHIMNEY CAP
A chimney cap is a crucial element for the heating appliance to work well: we recommend a wind resistant type (A) chimney cap,
see Fig. 9.
Fig. 9 - Examples of chimney caps
The area of the openings for smoke extraction must be at least twice the cross-section of the flue/ducted system and shaped so
that, even in the event of wind, smoke is still extracted. It must prevent rain, snow, and any animals from getting in. The height
of the opening must be beyond the backflow area cause by the shape of the roof or any obstacles that may be nearby (see Fig. 4,
Fig. 5, Fig. 6, Fig. 7 and Fig. 8).
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel IDRO PRINCE 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel IDRO PRINCE 30 in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel IDRO PRINCE 30

Cadel IDRO PRINCE 30 User Manual - German - 76 pages

Cadel IDRO PRINCE 30 User Manual - Dutch - 72 pages

Cadel IDRO PRINCE 30 User Manual - French - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info