perature is high enough (after about 5-8 minutes), ignition is considered to be completed.
Once the ignition step is complete, the stove moves into operating mode and shows the selected heat output, the ambient
temperature and the big flame (see Fig. 10).
If the ambient temperature value exceeds the limit set on the button panel in the temperature set, the heat output is brought
to its lowest value and the small flame is shown (see Fig. 11). When the ambient temperature decreases below the set tem-
perature, the stove goes back to the set output.
Fig. 10 - Big ame Fig. 11 - Small ame
8.7 FAILED IGNITION
If pellets should not ignite, the lack of ignition will be signalled by the A01 "No Ignition" warning.
If the ambient temperature is below 5°C, the resistance may not heat up enough to guarantee the pallet ignition. In this case,
remove the unburned pellets from the burning pot and restart ignition.
Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create dense white smoke
which is harmful to health and can cause explosions on the combustion chamber. It is therefore necessary not to stand in front of
the stove during ignition stage if dense white smoke is present.
If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the
burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue.
8.8 SWITCH OFF ON PANEL: OFF WITH FLASHING FLAME
If the shutdown key is pressed or if there is an alarm signal, the boiler goes into the thermal shutdown phase which entails the
automatic execution of the following stages:
Pellet loading is stopped.
The room fan continues to operate until the requested temperature is reached.
The flue fan is set to its highest value, which it keeps until the requested temperature is reached, plus a safety time of 10
additional minutes. After that, if the fume temperature has decreased below the switch off threshold, it stops, otherwise the
cooling process goes on.
If the stove has switched off normally, but owing to thermal inertia, the fume temperature goes over the threshold again, the
switch off process is reactivated until the temperature decreases again.
8.9 POWER FAILURE
After a black-out lower than 10 seconds, the stove turns back to the power which was settled.
After a black-out of more than 10 seconds, the stove enters the during shutdown. Completed this phase, it starts automatically
up with the different phases.
8.10 ADJUSTMENTS MENU
To access the adjustments menu act as follows:
Press the + - keys
Scroll with the <> arrows and select “Set Room T ” or Air Fan Speed 1” or Air Fan Speed 2” or “Comfort Mode” or "Fire"
Press “menu to access the selected option.
Modify with the + - keys.
Press “menu to confirm and esc” to exit.
Set Room T. - this function allows setting the desired temperature in the room where the stove is installed, starting from a mi-
nimum of 5°C up to a maximum of 35°C. When this condition is met, the stove reaches the minimum consumption values (flame
and hot air fan speed at minimum values) and then goes back to theset values when the ambient temperature goes below the set
threshold (see Fig. 12).
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel ICON PLUS 9 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel ICON PLUS 9 in the language / languages: English as an attachment in your email.

The manual is 0.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel ICON PLUS 9

Cadel ICON PLUS 9 User Manual - German - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info