643525
41
Zoom out
Zoom in
Previous page
1/56
Next page
41
AQUOS - IBIS - IDRON
EN
Enter MENU
Scroll to SLEEP with the <> arrows
Press Menu
With the + - keys adjust the desired shutdown time.
The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day
(I can therefore delay the shutdown for up to a maximum of 23 hours and 50 minutes).
If the SLEEP function is active with the TIMER active the rst has priority over the latter, therefore the boiler will not
switch off at the time set on the timer but instead by the time established by the sleep function, even if later than
the time set on the timer.
13.10 AUXILIARY BOILER (SEE SECTION I SETTINGS MENU PAGE 30)
One must install an additional module (optional) to enable start-up of an auxiliary boiler in the event the stove
is switched off or in alarm conditions. By default this function is deactivated, if needed activate it to access the
settings menu.
13.11 PELLETS RECIPE (SEE SECTION J SETTINGS MENU PAGE 30)
This function is for adapting the stove to the pellets that are being used. In fact, as there are several types of
pellets on the market, boiler operation is extremely variable depending on the fuel quality. In the event the
pellets tend to clog the brazier due to an excessive load of fuel or in the event the ame is always high even at
low powers and, vice versa if the ame is low one can decrease/increase the amount of pellets in the brazier:
The available values are:
-3 = Decrease by 30% compared to factory settings.
-2 = Decrease by 20% compared to factory settings.
-1 = Decrease by 10% compared to factory settings.
0 = No variation.
1 = Increase by 5% compared to factory settings.
2 = Increase by 10% compared to factory settings.
3 = Increase by 15% compared to factory settings.
13.12 SMOKE RPM VARIATION (SEE SECTION K SETTINGS MENU PAGE 30)
If the installation presents difculties for smoke evacuation (no draught or no pressure in the duct), the smoke
and ash expulsion speed can be increased. This change resolves all the potential problems related to pellets
clogging in the brazier and deposits forming at the bottom of the brazier itself caused by poor quality fuel or fuel
that produces a lot of ashes. The values available are from -30% to +50% with variations of 10 percentage points
at a time. The variation in negative can be used in case the ame is too low.
13.13 PUMP ON T (EXPERIENCED USERS ONLY) - SEE SECTION H SETTINGS MENU PAGE 30
This menu item allows to adjust the pump activation temperature.
13.14 MAXIMUM POWER (EXPERIENCED USERS ONLY) - SEE SECTION L SETTINGS MENU PAGE
30
It allows to set the maximum ame limit at which the boiler can operate to reach the set temperature target.
13.15 CHIMNEY SWEEP FUNCTION (FOR MAINTENANCE TECHNICIANS ONLY) - SEE SECTION N
SETTINGS MENU PAGE 30
This function can be activated only when the boiler is on and with power output and heating operation power
with parameters P5, with fan (if present) in V5. Any loading/smoke ventilation percentage corrections must be
taken into account. This status lasts 20 minutes, the countdown is displayed on the panel. During this interval the
thermostat/puffer/room set point/H20 set point are not taken into account, only the safety shutdown at 85°C
remains active. At any time the technician can interrupt this stage by quickly pressing the on/off key.
13.16 SEASON FUNCTION (SEE SECTION P SETTINGS MENU PAGE 30)
In congurations 2 and 3, by enabling the “summer” function, the deviation of the 3-way valve to the heating
system is inhibited in order to prevent the radiators from heating up, therefore the ow is always directed towards
the domestic hot water (DHW) - if envisaged.
By activating the “summer” option one automatically enables the auto-eco function (it cannot be deactivated).
The room probe/external thermostat are not taken into account.
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel Ibis 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel Ibis 15 in the language / languages: English as an attachment in your email.

The manual is 6,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel Ibis 15

Cadel Ibis 15 Usermanual and installation guide - German - 56 pages

Cadel Ibis 15 Usermanual and installation guide - Dutch - 56 pages

Cadel Ibis 15 Usermanual and installation guide - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info