696852
38
Zoom out
Zoom in
Previous page
1/72
Next page
IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 -
TESIS 16-23
AIRTIGHT - HIDROFIRE 22.8
38
LEGEND Fig. 43
2 Safety valve
3 Filling valve
4 Domestic hot water outlet
5 Domestic hot water entry
6 Heating return
7 Heating delivery
7.7 3 BAR DISCHARGE VALVE
There is a safety valve that can be inspected on the back of the stove under the pump. IT IS MANDATORY to connect a rubber hose
that is resistant to temperatures up to 110°C (not supplied) to the safety exhaust and run it to the outside in case water is discharged.
The manufacturer of the appliance is not liable for any flooding caused by the safety valves tripping if they
are not properly coupled to the outside of the product or to an appropriate collection and extraction system.
Fig. 44 - Discharge valve
LEGEND Fig. 44
A 3 bar CE PN10, TMAX 110°C safety valve
B ATTENTION: 110°C !!
7.8 SYSTEM CONNECTIONS
Make the connections to the corresponding fittings shown on the diagram on the previous page, taking care to avoid tension in
the pipes and undersizing.
WE STRONGLY RECOMMEND WASHING THE ENTIRE SYSTEM BEFORE CONNECTING THE STOVE IN ORDER TO RE-
MOVE RESIDUE AND BUILD-UPS.
Always install gate valves upstream of the stove to isolate it from the hydraulic system should it be necessary
to move it for routine and/or special maintenance. Connect the stove using flexible hoses so as not to excessi-
vely bind the stove to the system and to allow it to be moved slightly.
The pressure discharge valve (C) must always be connected to a water discharge pipe. The pipe must be suita-
ble to withstand the high water temperature and pressure.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel HIDROFIRE 22.8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel HIDROFIRE 22.8 in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel HIDROFIRE 22.8

Cadel HIDROFIRE 22.8 User Manual - German - 76 pages

Cadel HIDROFIRE 22.8 User Manual - Dutch - 72 pages

Cadel HIDROFIRE 22.8 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info