696852
10
Zoom out
Zoom in
Previous page
1/72
Next page
IDRO PRINCE
3
12-16-23-23 H
2
O - IDRO PRINCE 30-30 H
2
O - AQUOS
3
16-23-23 H
2
O - IDRON 16-22 AIRTIGHT - MIRA 16-22 -
TESIS 16-23
AIRTIGHT - HIDROFIRE 22.8
10
Fig. 2 - Safety distance
MODEL NON-FLAMMABLE WALLS FLAMMABLE WALLS
IDRO PRINCE
3
12 A = 5 cm / B = 5 cm A = 20 cm / B = 20 cm
IDRO PRINCE
3
16-23-23 H2O A = 5 cm / B = 5 cm A = 20 cm / B = 20 cm
IDRO PRINCE 30-30 H2O A = 5 cm / B = 5 cm A = 20 cm / B = 20 cm
AQUOS
3
16-23-23 H2O A = 5 cm / B = 5 cm A = 20 cm / B = 20 cm
IDRON 16-22 AIRTIGHT A = 5 cm / B = 5 cm A = 20 cm / B = 20 cm
HIDROFIRE 22.8 A = 5 cm / B = 5 cm A = 20 cm / B = 20 cm
If the floor is made of combustible material, we recommend using a protector made of incombustible material (steel, glass) that
also protects the front part from any falling burnt particles during cleaning.
The appliance must be installed on flooring that has an appropriate load-bearing capacity.
If the existing construction does not meet this requirement, appropriate measures must be taken (for example, a load distribution plate).
3.5 FOREWORD
This Flue chapter was written in reference to European standard requirements (EN 13384 - EN 1443 - EN 1856 - EN 1457).
It provides some instructions on how to properly install the flue but it does not in any way replace the standards in force, of which
the qualified manufacturer must be in possession. Check with the local authorities whether there are stricter standards regarding
the combustion air vent, the smoke exhaust system, the flue, the chimney cap.
The company declines all liability regarding poor stove operation if it can be attributed to using an incorrectly sized flue that does
not meet the standards in force.
3.6 FLUE
The flue or chimney is extremely important for forced draft heating appliances fired by solid fuels to work properly, as modern
heating appliances are high performing with cooler smoke and, as such, less draft. Thus, it is fundamental for the flue to be built
properly and always kept perfectly efficient. A flue serving a pellet/wood appliance must be at least category T400 (or above if
the appliance requires it) and resistant to soot fire. Smoke must be extracted via individual flue with insulated steel pipes (A) or
existing flue and must comply with the intended use (B).
A simple cement cavity must be appropriately ducted. Both solutions require an inspection cap (AT) and/or inspection door (AP) - FIG.1.
Do not connect more than one wood/pellet or other types (exhaust hood) of appliance (*) to the same flue.
(*) unless there are national exceptions (for example, in Germany), which allow more than one appliance to be installed in the same
chimney under opportune conditions; in any case, scrupulously follow the product/installation requisites provided for by the corre-
sponding standards/laws in force in the country
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel HIDROFIRE 22.8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel HIDROFIRE 22.8 in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel HIDROFIRE 22.8

Cadel HIDROFIRE 22.8 User Manual - German - 76 pages

Cadel HIDROFIRE 22.8 User Manual - Dutch - 72 pages

Cadel HIDROFIRE 22.8 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info