696348
10
Zoom out
Zoom in
Previous page
1/35
Next page
GRACE
3
- SPIRIT
3
- MADISON - TABLA - ROXY - ATRIUM
10
We recommend to check with your chimney flue manufacturer the safety distances which must be respected
and the type of insulating material. The aforesaid regulations are valid also for holes made on the wall (EN
13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).
4 COMBUSTION AIR
4.1 EXTERNAL AIR INLET
Fig. 9 - Direct air inow
LEGEND Fig. 9
1 Room to ventilate
2 External air inlet
The room must be endowed with an external air recycling for a good climate in your ambient.
The air inflow from outside to the inner occurs directly, through an opening on the external wall of the room (see Fig. 9).
Bedrooms, garages, and store of flammable materials are excluded.
The air inlet should have a total net surface of 80 sqcm
2
: the aforesaid surface is to widen if inside the room there are other
activated appliances (for example: electric ventilators for foul air suction, cooker hoods, other stoves, etc...) which depress the
environment.
At switched on appliance it is necessary to check that the pressure fall between the room and the outside does not exceed 4,0
Pa value: if necessary widen the air inlet (EN 13384).
The air inlet must be realized at a height close to the floor with an external grid against birds. In such a way it cannot be ob-
structed by any object.
In case of installation with sealed-chamber the air inlet is not necessary.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel GRACE3 - 2019 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel GRACE3 - 2019 in the language / languages: English as an attachment in your email.

The manual is 5,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel GRACE3 - 2019

Cadel GRACE3 - 2019 User Manual - English - 32 pages

Cadel GRACE3 - 2019 Installation Guide - German - 35 pages

Cadel GRACE3 - 2019 User Manual - German - 32 pages

Cadel GRACE3 - 2019 Installation Guide - Dutch - 35 pages

Cadel GRACE3 - 2019 User Manual - Dutch - 32 pages

Cadel GRACE3 - 2019 Installation Guide - French - 35 pages

Cadel GRACE3 - 2019 User Manual - French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info