814915
7
Zoom out
Zoom in
Previous page
1/32
Next page
7
GRACE - SPIRIT 5 - ATRIUM 5 - SOLO - ROXY - TABLA - MADISON 5
Fig. 5 - Anti-wind chimney pots Fig. 6 - Reux area
3.6 MAINTENANCE
The fumes extraction pipes (fumes conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked
by an expert stove-repairer, in compliance with current regulations, with the instructions of the stove-manufacturer and the
directives of your insurance company.
In case of doubts, please follow the most restrictive regulations.
Have your chimney flue and chimney pot checked and cleaned by an expert chimney sweep at least once a week. The chimney
sweep has to release a written declaration about the security of the system.
Not cleaning compromise safety.
4 COMBUSTION AIR
4.1 AIR INLET
It is mandatory to provide an adequate external air inlet that supplies the combustion air required for the product to work properly.
The flow of air between the outside and the installation room can take place with a free air inlet or by channelling the air directly
to the outside (***).
The free air inlet must be:
be made at floor level and in any case not higher than the height of the appliance;
always be protected with an outer grille and in such a way that it cannot be obstructed by any object;
have a minimum total free area of 80 cm2 (net of the grille);
The presence of other suction devices (e.g.: vmc, electric fan for stale air extraction, kitchen hood, other stoves, etc.), in the same
room,or in communicating rooms of the same housing unit, could cause negative pressure in the room. In this case, with the
exception of sealed installations, one must verify that, with all the equipment on, no more than 4 Pa of negative pressure is created
inside the installation room with respect to the outside. If necessary, increase the air inlet section.
It is possible to duct the air required for combustion to the outside by connecting the external air inlet directly with the combustion
air inlet which is usually found on the back of the appliance.
The external ducted air vents must be:
made close to the floor and anyway not higher than the appliance
protected by a grille that guarantees a clear surface equal to the cross-section of the duct and made so that it cannot be ob-
structed by any object
The air vent can be made directly on a wall of the installation room communicating with the outside, or indirectly in adjacent
rooms that permanently communicate with the installation room, according to that set forth by standards in force.
The duct must comply with the following dimensions (each 90° bend is equivalent to one linear metre):
(***) In the event the combustion air is ducted on unsealed products, still verify that no more than 4 Pa of negative pressure is created
inside the installation room with respect to the outside, otherwise provide for an additional air intake in the room.
Below 15 kW:
Air duct diameter Maximum length (smooth duct) Maximum length (corrugated duct)
50 mm 2 m 1 m
60 mm 3 m 2 m
80 mm 7 m 4 m
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel GRACE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel GRACE in the language / languages: English as an attachment in your email.

The manual is 2.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel GRACE

Cadel GRACE User Manual - English - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info