VENUS - GIOIA
EN
10.6 STOVE ADJUSTMENT
The stove is adjusted according to the chimney ue and used pellets datas, as per technical characteristics
(see FEATURES page 100). If the datas do not correspond, the authorized technician can adjust the stove.
If the pellet is small in size and with a greater caloric power, (for example: encrusted burning pot), the
pellet drop must be decreased from the menu “FLAME SETTING”, press P3 “PELLET TYPE”, press P3 again
“PELLET LOAD” and with P2 key decrease the pellet quantity from -1 (which is -2%) till -9 (which is -18%).
If the chimney ue has a lower draught (for example: weak ame, sooty glass) the revolutions of the
geared motor must be increased from the menu “FLAME SETTING”, press P5 “CHIMNEY TYPE”, press P3
“FUME-EXT, CHIMNEY” and with P1 key increase the fume fan revolutions from +1 (which is +5%) till +9
(which is +30%).
If the chimney ue has a greater draught (for example: because of pellets fall on the burning pot)
decrease the fume fan revolutions from -1 to -9.
Pay attention if the value is positive or negative..
10.7 FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm “NO IGNITION”.
If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support
it please insert some pellets in the burning pot and a piece of burning relighter igniter material on the
pellets (for example relighters cubes).
After a failed ignition the burning pot must be empty from the amassed pellets, before
starting the stove up again.
Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difcult and
create dense white smoke which is harmful to health and can cause explosions on the combustion
chamber. It is therefore necessary not to stand in front of the stove during ignition stage if dense white
smoke is present.
If after some months the ame appears weak and/or orange colored or the glass tends
to blackens and the burning pot to become encrusted, clean the stove, clean the
fume conduit and the chimney ue.
10.8 POWER FAILURE
After a black-out lower than 5 seconds, the stove turns back to the power which was settled.
After a black-out of more than 5 seconds, the stove enters the “COOLING WAIT” phase. Completed this
phase, it starts automatically up with the different phases (see START UP page 77).
10.9 TEMPERATURE SETTING
To modify the ambient temperature it is sufcient to press P1 and P2 keys according to the desired
temperature inside the menu “SET TEMP ROOM”.
To see the set temperature, press once P1 key.
10.10 FUME TEMPERATURE
To check the fume temperature at the exhaust it is sufcient to keep pressed P2 key.
78


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel Gioia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel Gioia in the language / languages: English, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 8,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info