814947
20
Zoom out
Zoom in
Previous page
1/36
Next page
KOBE - FENICE - SPARK - INDACO - PRINCE - GO - ECLIPSE
20
In the boiler on and timer active condition, press the OFF key and the boiler will switch off, it will switch on automatically at
the next time set on the timer.
In the boiler off and timer active condition, press the ON key and the boiler will switch on, it will switch off at the time set on
the active timer.
8.14 AUTO ECO MODE SEE SECTION FG SETTINGS MENU A PAG. 14
To activate the Auto-Eco mode and adjust the time refer SETTINGS MENU a pag. 14.
The possibility to adjust the t Off Time Eco comes from the need to ensure proper operation in the various rooms the boiler can
be installed in and prevent continuous shutdowns and start-ups in the event the temperature is subject to sudden changes (air
currents, poorly insulated rooms, etc.).
The ECO switch off procedure is automatically activated when the power recall device is activated (Room probe +1°C or external
thermostat with open contact, see Fig. 19). "t Off Time Eco" time decrease starts (5 minutes by default, see Fig. 20, and can be
modified from the "Settings" menu). During this phase the panel view is activated ON with the small flame and alternates chrono
(if ON) - active Eco.
Fig. 19 - Active eco 1 Fig. 20 - Active eco 2 Fig. 21 - Active eco 3
On the upper display the minutes for the Eco Stop countdown are shown. The flame goes to P1, where it remains until the set "t
Off Time Eco" time is over and, if conditions are still met, it switches to the switch-off process. The ECO switch-off countdown is
reset if one of the devices resumes recalling power.
When the switch-off procedure begins, the panel shows: Off - Active Eco - small flashing flame (see Fig. 21).
When the stove is switched off, the panel shows active OFF-ECO with the flame icon off.
For an ECO switch on, the following conditions must be met simultaneously:
Room probe -1°C or external thermostat with closed contact (for at least 20" to avoid false recalls).
After 5 minutes from the beginning of the switch-off procedure.
8.15 SLEEP FUNCTION MAIN MENU
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the product must
switch off.
To set the Sleep function act as follows:
Enter MENU
Scroll to SLEEP with the <> arrows
Press Menu
With the + - keys adjust the desired shutdown time.
The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the next day (I can therefore
delay the shutdown for up to a maximum of 23 hours and 50 minutes).
Fig. 22 - Sleep
If the SLEEP function is active with the TIMER active the first has priority over the latter, therefore the boiler will not switch off at
the time set on the timer but instead by the time established by the sleep function, even if later than the time set on the timer.
8.16 EASY SET FEATURE SEE SECTION X SETTINGS MENU A PAG. 14
Proper operation of a stove mainly depends on the flue it is connected to. Once it is connected, it is equally important to perform
proper adjustment of combustion parameters.
The Easy Set feature makes it possible to adjust combustion more easily, in the event that one should notice that the stove does
not properly burn the fuel.
In the “Settings” menu, under the heading Easy Set, there are 4 configurations, SET1-SET2-SET3-SET4.
Select the SET based on the type of installation.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel FENICE PLUS 11 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel FENICE PLUS 11 in the language / languages: English as an attachment in your email.

The manual is 0.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel FENICE PLUS 11

Cadel FENICE PLUS 11 User Manual - German - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info