EN
Old chimney ue with an inserted pipe of minimum Ø160 mm and with an external door which enables the
chimney cleaning.
Fig. 10 - Example 3
LEGEND Fig. 10 page 12
1 Insulating material
2 Inspection plug
3 Minimum safety distance = 0,5 mt
4 Damper
External chimney ue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø150
mm: all must be rmly attached to the wall. For chimney against wind effects please (see Fig. 4 page 8).
Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
We recommend to check with your chimney ue manufacturer the safety distances which
must be respected and the type of insulating material. The aforesaid regulations are valid
also for holes made on the wall (EN 13501 - EN 13063 - EN 1856 - EN 1806 - EN 15827).
9
FUEL
9.1 FUEL
The allowed fuel is rewood and its derivatives (lignite blocks, compressed sawdust, etc.) with a maximum
water content of 20%.
To obtain good rewood, it must be seasoned outside for at least 2 years in a place protected from the
weather.
Using humid wood or waste bark could create condension and creosote into the ductions and in the hearth.
A heat yield of humid wood is great lower than dry wood.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel DEMETRA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel DEMETRA in the language / languages: English as an attachment in your email.

The manual is 4,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel DEMETRA

Cadel DEMETRA Usermanual and installation guide - French, Italian - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info