AQUOS - IBIS - IDRON
EN
Fig. 3 - Pellet stove installation example
5.6 CONNECTIONS
CONNECTION TO THE FLUE PIPE
CONNECTION TO AN EXTERNAL DUCT
WITH AN INSULATED OR DOUBLE-WALL PIPE
CONNECTION TO THE FLUE PIPE
The internal dimensions of the chimney
pipe must not exceed 20x20 cm or
20 cm in diameter; in the event of
bigger sizes or bad chimney conditions
(e.g. cracks, poor insulation, etc.), it is
advisable to t a stainless steel pipe
of suitable diameter throughout the
length of the chimney right to the top.
The minimum internal dimensions of the
external duct must be 10x10 cm or 10 cm
in diameter and must not exceed 20x20
cm or 20 cm in diameter. Only stainless
steel insulated (double-wall) pipes must
be used, which are smooth on the inside
and xed to the wall. Flexible stainless
steel pipes must not be used.
The connection between the product
and the ue or the smoke duct must
not have an inclination below 3% in the
horizontal sections, which must have a
maximum overall length of 2/3 m. The
vertical section between one T-tting
and another (angle) must not be less
than 1.5 m.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadel Aquos 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadel Aquos 15 in the language / languages: English as an attachment in your email.

The manual is 6,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadel Aquos 15

Cadel Aquos 15 Usermanual and installation guide - German - 56 pages

Cadel Aquos 15 Usermanual and installation guide - Dutch - 56 pages

Cadel Aquos 15 Usermanual and installation guide - French - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info