If there is a leak on your appliance (smell of gas), close the cylinder valve immediately and take it into a  ame free location where the leak
may be detected and stopped. If you wish to check for leaks on your appliance, do it outside. Do not try to detect leaks using a  ame; use
soapy water.
The correct way is to smear the joints e.g. where the stem  ts into the cylinder, with
soapy water.
If bubbles form, then there is a gas leak. Immediately turn off the gas supply by
closing the control valve on the gas container and then the appliance valve. Check
that all the connections are properly  tted. Re-check with soapy water.
If a gas leak persists, return the product to your CADAC dealer for inspection / repair.
Use Outdoors Only.
Fig. 3
Fig. 5
Fig. 1
Fig. 2
Seal
Cylinder Valve
Fit hose
clamp
here
RegulatorHose
3. Assembly Instructions
WARNING: The legs are spring loaded. Opening and closing of the legs must
be done in a controlled manner to avoid personal injury or damage to your
Camp Chef.
To open the legs, turn the unit upside-down and hold the legs down while lifting
each leg individually. You will hear a “click“ if the leg(s) has located correctly.
To fold the legs back, securely hold the leg and push the Leg Release Clip down.
Then push the legs in-ward to its closed position (Fig 6). This needs to be done
sequentially to optimise space. First the Right front leg (1), Then the
Left front leg (2), and lastly the rear Leg (3) (Fig 4b).
Before connecting the gas supply,  rstly check that the appliance valve is in the off
position by turning the control knob fully clockwise (See Fig. 2).
I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37) Appliance categories: Fit the Valve
Tailpiece onto the Valve (Fig.5) by screwing it on in an anti-clockwise direction.
Push an 8mm inside diameter Hose onto the Valve Tailpiece until it is properly
seated. On the other end attach a suitable 30mbar low-pressure (I 3B/P (30) and
I 3+ (28-30/37) Butane con gurations) or 37mBar low-pressure regulator (I 3+
(28-30/37) Propane con guration), again making sure that the hose is well seated.
The hose used must comply with BS 3212 / SABS 1156-2 or equivalent.
I 3B/P (50) Appliance category: Screw a Hose with the correct threaded  ttings on
each end, onto the left hand ¼“BSP thread of the Valve. Attach a suitable 50mbar
low-pressure regulator on the other end of the hose. The hose used must comply
with DIN 4815 part 2 or equivalent.
Note: The hose and regulator are not supplied with the appliance. For details,
contact your local stockist.
The hose length should be no less than 800 mm and shall not exceed 1.5 m.
Check the expiry date on the hose and replace when necessary or when national
conditions require it. Do not twist or pinch
hose.
Your appliance is now ready for use.
OFF
Fig. 4a
Fig. 4b
Fig. 4a
Fig. 4b Fig. 4c
28-30 & 37mbar
ONLY
GB
503-0573 LEV12 (6530L0, 6530L1) Camp Chef LP - User Manual - (EU + SA).indd 2 15/08/2017 13:09:28
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cadac 6530L1 - Camp Chef LP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cadac 6530L1 - Camp Chef LP in the language / languages: English as an attachment in your email.

The manual is 0,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cadac 6530L1 - Camp Chef LP

Cadac 6530L1 - Camp Chef LP User Manual - German - 7 pages

Cadac 6530L1 - Camp Chef LP User Manual - Dutch - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info