Installatie- en onderhoudshandleiding ThermoSystem HR TS 0020080029_0054
15.6 Verbrandingslucht-/rookgasleiding – onafhan-
kelijk van de omgevingslucht, verbrandings-
lucht door de buitenmuur, rookgasleiding op
de gevel
L
1
L
4
L
2
L
3
min . 1 m
Afb. 15.4 Verbrandingslucht-/rookgasleiding - onafhankelijk van
de omgevingslucht, verbrandingslucht door de buiten-
muur, rookgasleiding op de gevel
Toesteltype Maximale totale buislengte (L
1
+ L
2
+ L
3
+ L
4
)
DN 130 DN 140 DN 150 DN 200
ThermoSystem HR TS 80/3 30,0 30,0 50,0
ThermoSystem HR TS 120/3 30,0 30,0 50,0
ThermoSystem HR TS 160/3 30,0 30,0 50,0
ThermoSystem HR TS 200/3 50,0
ThermoSystem HR TS 240/3 50,0
ThermoSystem HR TS 280/3 50,0
Max. lengte van de horizontale leidingen: telkens 4 m verbrandingsluchtleiding en 2 x 87°-bochtstukken en 4 m rookgasleiding en
2 x 87°-bochtstukken
Minimum diameter van de verbrandingsluchtleiding 150 mm
Minimale weerstand tegen warmtedoorgang van de rookgasleiding in de koude ruimte 0,4 m
2
K/W
Tabel 15.5 Maximale totale buislengtes (verbrandingslucht door
de buitenmuur, rookgasleiding op de gevel)
15 Gekeurde en toegelaten verbrandingslucht-/rookgasleidingen –
onafhankelijk van de omgevingslucht
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bulex Thermo SYSTEM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bulex Thermo SYSTEM in the language / languages: Dutch as an attachment in your email.

The manual is 5,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info