Niveau ZON SYSTEEM (..VV..)
De parameters in dit niveau hebben betrekking op speciale instellingen met betrekking tot
de zonnetoepassingen. De vrijschakeling gebeurt alleen bij dienovereenkomstige
activering in het hoofdstuk HYDRAULICA.
PARAMETER
Aanduiding Instelbereik / Instelwaarden
Fabrieks-
instelling
Instelling
01 Inschakelverschil (Uitschakelverschil +3 K) ... 30 K
10 K
02 Uitschakelverschil 2 K ... (Inschakelverschil -3 K)
5 K
03 Temperatuurverhoging ZLP 0 ... 60 Min
3 Min
04
Zonne-collector-
Maximumtemperatuur
90 ... 250 °C
120 °C
05
Zonnereservoir-
maximumbegrenzing
50 ... 110 °C
75 °C
06 Zonne-programma
1 Prioriteitbedrijf
2 Parallelbedrijf
2
07
Klokblokkering
warmteopwekker
UIT, 0,5...24 h
(Alleen bij prioriteitbedrijf- Parameter 6 = 1)
UIT
08 Zon. Prior./Parallelomsch.
UIT, 1..0,30 K
(alleen bij prioriteitbedrijf en act.
klokblokkering)
UIT
09 Zonne-warmtebalans
UIT geen warmtebalans
1 Balans door
doorstroomvoorschrift
2 Balans door impulsevaluatie
UIT
RESET ZON Terugzetten warmtebalans
Terugzetten: bij SET draaiknop indrukken
(alleen bij geactiveerde zonne-
warmtebalans)
-
11 Volumestroom
0,0 ... 30 liter/min resp. liter/impuls
(alleen bij geactiveerde zonne-
warmtebalans)
0,0 l/min
12
Dichtheid warmtedr
ager
0,8 ... 1,2 kg/liter
(alleen bij geactiveerde zonne-
warmtebalans)
1,05 kg/l
13
Specifiek warmtevermogen
warmtedragermedium
2,0 ... 5,0 KJ/kgK (alleen bij geactiveerde
zonne-warmtebalans)
3,6
KJ/kgK
14 Einduitschakeltemperatuur UIT, 90...210°C
150°C
15
Testcircuit
solarlaadomschakeling
1...60 min
10 min
16 Omschakeltemperatuur 50...110°C
75°C
Niveau VASTE BRANDSTOF (..VV..)
De parameters in dit niveau hebben betrekking op speciale instellingen met betrekking tot
de vaste brandstofregeling. De vrijschakeling gebeurt alleen bij dienovereenkomstige
activering in het hoofdstuk HYDRAULICA.
PARAMETER
Aanduiding Instelbereik / Instelwaarden
Fabrieks-
instelling
Instelling
01 Minimumtemperatuur 20 ... 80 °C
60 °C
02 Maximumtemperatuur 30 ... 100 °C
90 °C
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bulex Module T-box 3 zones at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bulex Module T-box 3 zones in the language / languages: Dutch as an attachment in your email.

The manual is 13,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info