678317
155
Zoom out
Zoom in
Previous page
1/160
Next page
155
RAID Arrayx E14
Can’t Mount
RAID array X cannot be mounted. Run the RAID array disk check in Settings.
HDx Error E16
HDx Not Found
Unable to find hard drive X.
Hard drive X may be disconnected or may
have failed. After shutting down, reinstall the
hard drive.
HDx Error E22
HDx Can’t Mount
Mounting of hard drive X failed.
Format the hard drive. After formatting,
if the error still appears after rebooting,
replace the hard drive. If the error is displayed
again, contact Buffalo technical support for
assistance.
FailOver E27
LostBackupTarget
Unable to find the backup TeraStation.
In the main TeraStations settings, navigate to
Backup - Failover to reconfigure the backup
TeraStation for failover.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive X was
removed from the RAID array.
Replace hard drive X.
E31 Power supply error (level 1)
Make sure that the AC cable is connected
properly. If the power supply has failed, E32
will be displayed within a few minutes. If E31 is
still displayed after 5 minutes, contact Buffalo
technical support for assistance.
E32 Power supply error (level 2)
Make sure that the AC cable is connected
properly. If the power status LED is blinking or
glowing red, replace the power supply with a
new Buffalo OP-PU-2RZ.
Status
After you change settings or format a hard drive, the current status is displayed on NAS Navigator2 or clicking in
Settings.
Message Description Corrective Action
HDx Warning I11
Bad Sectors
The bad sectors in hard drive x may
have reached a dangerous level.
Replace hard drive x.
Operation I12
DEGRADE MODE
Operating in degraded mode. -
RAID I13
ARRAYxFormatting
Formatting RAID array x. -
RAID I14
ARRAYx Checking
Checking RAID array x. -
RAID I15
ARRAYx Scanning
Examining the error status of RAID
array x.
Note: Transfer speeds are slower
during the examination process.
-
RAID I16
ARRAYx Creating
Creating RAID array x. -
RAID I17
ARRAYx Resyncing
Resynchronizing RAID array x.
Note: Transfer speeds are slower
during resynchronization.
-
155


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buffalo TeraStation 7120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buffalo TeraStation 7120 in the language / languages: English as an attachment in your email.

The manual is 6,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info