784865
37
Zoom out
Zoom in
Previous page
1/40
Next page
37
HEAT.WAV WATER HEATER CONNECTIONS
All Y Series systems come with a high performance heat.wav
heater. With no pressure switch, it features in.flo integrated
dry-fire protection.
The heat.wav heater is factory configured for 240 V / 4 kW,
but it can be converted to a dedicated 120 V / 1 kW by simply
adding a cable connection. (120 V conversion is available on
North American in.ye-3 models only).
The heat.wav heater is also offered in 240 V / 5,5 kW or 240 V
/ 2 kW versions.
heat.wav specification summary:
• Supports 120 V or 240 V
• Incoloy® heater element
• Protected by external breaker (not fused)*
* Note: European models are 230-240 V only and are fuse
protected.
Part numbers:
9917-101959 (cable for conversion)
9920-101449 (5.5 kW heat.wav heater)
Connections for 120 V
heaters (1 kW)
BROWN wire must be cor-
rectly connected between
P12 and P10.
For early North American ver-
sion installations the YELLOW
wire must be between P25
and P20.
The ORANGE wire must be
between P24 and P16.
Connections for 240 V
heaters (North American
installations only).
BROWN wire must be cor-
rectly connected between
P12 and P9.
Note: To convert model to a
120 V system, the white (com-
mon) accessory wire must be
moved. See wiring diagram
for details.
CONNECTIONS
WIRING DIAGRAM  W3000
All heater connections are accessible when the cover is removed. Connections include the in.flo dry-fire protection, hi-limit/
regulation probe connectors, power and ground cable connections.
Live Return Ground in.flo flo Regulation probe
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bueno Spa Boston at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bueno Spa Boston in the language / languages: English as an attachment in your email.

The manual is 6.43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info