SSB 6720818455 (2016/02) CA
Installation | 27
Diamètre de tuyau par chaudière
Matériau Élément
Standard
[États-Unis]
Standard
[Canada]
SSB
255
SSB
399
SSB
512
Calendrier PVC
40, 80
1
Gaz de combustion
ou air de
combustion
ANSI/ASTM D1785
Évacuation de
gaz BH
systèmes,
ULC S636
1
,
Classe IIA - PVC,
Classe IIB - CPVC,
Classe IIC -
Polypropylène
3 po (80mm)
4 po (100mm)
3” (80mm)
4” (100mm)
4 po (100mm)
PVC-DWV
Gaz de combustion
ou air de
combustion
ANSI/ASTM D2665
3 po (80mm)
4 po (100mm)
4 po (100mm) 4 po (100mm)
Calendrier CPVC
40, 80
Gaz de combustion
ou air de
combustion
ANSI/ASTM F441
3 po (80mm)
4 po (100mm)
4 po (100mm) 4 po (100mm)
PP
Gaz de combustion
ou air de
combustion
ANSI Cat IV
Polypropylène
approuvé
3 po (80mm)
4 po (100mm)
4 po (100mm)
5 po (130mm)
4 po (100mm)
5 po (130mm)
PP-Flex
Gaz de combustion
ou air de
combustion
ANSI Cat IV
Polypropylène
approuvé
3 po (80mm)
4 po (100mm)
4 po (100mm)
5 po (130mm)
4 po (100mm)
5 po (130mm)
Acier inoxydable
AL29-4C
Gaz de combustion
ou air de
combustion
UL1738
3 po (80mm)
4 po (100mm)
4 po (100mm)
5 po (130mm)
4 po (100mm)
5 po (130mm)
PVC
Ciment pour tuyau/
apprêt
ANSI/ASTM D2564 X X X
CPVC
Ciment pour tuyau/
apprêt
ANSI/ASTM F493 X X X
Tab. 4 Matériaux approuvés pour gaz de combustion ou pour air de combustion et raccords selon la chaudière
1 Le PVC ne doit pas être utilisé pour le matériau de ventilation lorsqu’un mélange de glycol est utilisé dans le circuit de la chaudière.
2 Les composants des systèmes de ventilation certiés ne doivent pas être échangés avec d'autres systèmes ou raccords de tuyauterie non
homologués. Les composants en plastique, et les apprêts spéciques, et colles du système de ventilation certié doivent provenir d'un même fabricant
de système et pas mélangés avec les pièces de système de ventilation d'un autre fabricant. Pour les installations au Canada, la tuyauterie d'évent
en plastique fournie sur le terrain doit se conformer à la norme CAN/CSA B149.1 (dernière édition) et être certiée conformément à la norme des
systèmes de ventilation de gaz de type BH. ULC S636.
Le connecteur de l'évent fourni et les terminaisons d'évent séparée disponible sont certiés comme faisant partie de la chaudière.
Les tuyaux droits standard, coudes ou tés de 90 ° sont approuvés comme des raccordements de toits ou de murs dans tous les matériaux approuvés. En
outre, les terminaisons suivantes sont approuvées. Pour plus de détails, de reporter aux données du fournisseur.
Raccordement de toit Matériau Fournisseur Numéro de pièce
3 po (125 mm)
4 po (100mm)
Kits concentriques
PVC ou CPVC
Système IPEX 636
Type IIa et IIb
196006 (PVC), 197009 (CPVC)
196021 (PVC), 197021 (CPVC)
3” / 5” (80/125 mm)
concentrique
PP
M&G Duravent PolyPro
ou
Centrotherm InnoFlue
3PPS-VKL (M&G Duravent)
ou
ICRT3539 (Centrotherm)
4 po/6 po (100/150 mm)
Concentrique
PP
M&G Duravent PolyPro
ou
Centrotherm InnoFlue
4PPS-VK (-TC) (M&G Duravent)
ou
ICRT 4679 (Centrotherm)
3 po (80 mm)
Mitre de cheminée
PP Flex
M&G Duravent PolyPro
ou
Centrotherm InnoFlue
3PPS-FCT(M&G Duravent)
ou
ISCP03 (Centrotherm)
4 po (100 mm)
Mitre de cheminée
PP Flex
M&G Duravent - PolyPro
Centrotherm - Innoue
SW Flex
4PPS FKL (M&G Duravent)
ou
ISCP04 (Centrotherm)
5 po (130 mm)
6 po (150 mm)
8 po (200 mm)
Raccordement vertical pour les
systèmes commerciaux
PP M&G Duravent - PolyPro
5PPS-VTM
6PPS-VTM
8PPS-VTM
Tab. 5 Raccordements de toits
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus SSB512 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus SSB512 in the language / languages: French as an attachment in your email.

The manual is 9,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus SSB512

Buderus SSB512 Installation Guide - English - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info