"Flow Switch Not Closed Error" 32Flow switch not working / No ow
"Flow Switch Not Open Error" 33Flow switch not working / No ow
"Flag Byte Integrity Error"34Internal software errorReplace the power control board
"Ad Hi Cpl Error"35Internal software errorReplace the power control board
"Ad Lo Cpl Error"36Internal software errorReplace the power control board
"Register Error"37Internal software errorReplace the power control board
Tab. 18 Lockout codes
6.1.2 Blocking errors
If it is “Blocking” error the boiler will go back to normal operation, with no need to press the “RESET” button, once the reason for the failure has been
eliminated.
In the following table the “Blocking” errors are listed:
ErrorInt. nr.DescriptionChecksSolutions
"WD Error Ram"45Internal software errorReplace the power control board
"WD Error Rom"46Internal software errorReplace the power control board
"WD Error Stack"47Internal software errorReplace the power control board
"WD Error Register"48Internal software errorReplace the power control board
"WD Error Xrl"49Internal software errorReplace the power control board
"Refhi Too Lo Error"50Internal software errorReplace the power control board
"Refhi Too Hi Error"51Internal software errorReplace the power control board
"Reo Too Lo Error"52Internal software errorReplace the power control board
"Reo Too Hi Error"53Internal software errorReplace the power control board
"Flame Error 2"54
Flame is detected in a state in which no
ame is allowed to be seen
Replace the power control board
"Water Level Detect"55Low water level detected
"Water Level Meas"56Low water level measurement error
"Low Water Cutoff Error"57Low water sensor errorCheck the LWCO
If the LWCO is in alarm, try to reset
it.
"Low Water Pressure Error"58Low water pressure error
"Low Water Pressure Sensor"59Low water pressure
"Flue Gas Error"60Flue gas pressure error
a- Check the ue gas
pressure switches
b- Check the gas pressure
a- If the ue gas pressure switches
don’t work, replace them
b- If the gas supply pressure is
incorrect, it must be adjusted to the
correct pressure pressure
"Return Temp Error"61
Return temperature is higher than stay
burning temperature
a- Check the return
temperature sensor
b- Verify the pump for ow
circulation
a- Verify that the temperature
sensor has the correct resistance
values. If values are incorrect
sensor must be replaced.
b- Change the pump or restart it
"Blocked Drain Error"62Block drain switch is active
"Wd Freq Error"64
Incorrect Frequency signal or no
communication with the WD
Verify the supplied 120 V ac
current
a- If the supplied 120 V ac current
has a frequency of 60HZ +/- 2% ,
replace the power control board
b- If the frequency is out of range,
consult electrician
"Phase Error"65Hot neutral reversed
Check the supply 120 V ac
connection
Reverse the supply voltage polarity
"Net Freq Error"66Net freq. error detected in the main
Check the frequency of the
supply 120 V ac connection
a- If the supplied 120 V ac current
has a frequency of 60HZ +/- 2% ,
replace the power control board
b- If the frequency is out of range,
consult electrician
"Faulty Earth Error"67Faulty earth connection
Check the earth connection
to the appliance
Restore the earth connection
"WD Communication Error"68Watchdog communication errorReplace the power control board
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Buderus SSB512 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Buderus SSB512 in the language / languages: English as an attachment in your email.
The manual is 9,92 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.