10 | Product description
2.7 Technical data
Unit SSB255 SSB399 SSB512
Boiler Category ASME Sect.IV ASME Sect.IV ASME Sect.IV
Type of Gas Natural Gas, Propane * Natural Gas, Propane * Natural Gas, Propane *
Max input rate BTU/hr (kW) 255,900 (75) 399,000 (117) 512,000 (150)
Min input rate BTU/hr (kW) 51,180 (15) 79,800 (23.4) 102,400 (30)
Turndown Rate (%) 5:1 (20 %) 5:1 (20 %) 5:1 (20 %)
Gas Connections (NPT) Ø Inch 1” 1’’ 1’’
Max. NG Pressure Inch W.C. (mbar) 10.5 (26.15) 10.5 (26.15) 10.5 (26.15)
Min. NG Pressure Inch W.C. (mbar) 3.5 (8.72) 3.5 (8.72) 3.5 (8.72)
Max. LPG Pressure Inch W.C. (mbar) 13 (32.3) 13 (32.3) 13 (32.3)
Min. LPG Pressure Inch W.C. (mbar) 8 (19.9) 8 (19.9) 8 (19.9)
Water Connections Ø Inch 1 ½ “ 1 ½” 2’’
Max. Allowable Working Pressure
(MAWP)
PSI (bar) 80 (5.5) 80 (5.5) 80 (5.5)
Recommended water ow @ max
power (∆T 36 °F / 20 °C)
GPM (m
3
/h) 14.2 (3.2) 22.2 (5.0) 28.4 (6.5)
Max water ow @ max power
(∆T 27 °F / 15 °C)
GPM (m
3
/h) 18.9 (4.3) 29.5 (6.7) 37.9 (8.6)
Min water ow @ max power
(∆T 54 °F / 30 °C)
GPM (m
3
/h) 9.5 (2.2) 14.8 (3.4) 18.9 (4.3)
Min water ow @ min power
(∆T 27 °F / 15 °C)
GPM (m
3
/h) 3.8 (0.9) 5.9 (1.3) 7.6 (1.7)
Water Pressure Drop @
recommended water ow
Feet Head (mbar) 3.8 (114) 8.3 (250) 21.7 (650)
Water Pressure Drop @ max water
ow
Feet Head (mbar) 6.4 (190) 13.8 (410) 37.73 (1120)
Water Volume Gallon (liter) 4.0 (15.2) 4.5 (17.0) 6.0 (23.0)
Vent/Air Intake Connections Ø Inch (Ø mm) 3 (80) 4 (100) 4 (100)
Vent Materials
CPVC, PVC, PP, PP Flex,
Stainless Steel AL29-4C
IPEX type IIA & IIB
CPVC, PVC, PP, PP Flex,
Stainless Steel AL29-4C
IPEX type IIA & IIB
CPVC, PVC, PP, PP Flex,
Stainless Steel AL29-4C
IPEX type IIA & IIB
Max operating temperature °F (°C) 194 (90) 194 (90) 194 (90)
Max HE allowable temperature °F (°C) 210 (98.9) 210 (98.9) 210 (98.9)
Ambient storage temperature dry °F (°C) 5 to 150 (-15 to 65) 5 to 150 (-15 to 65) 5 to 150 (-15 to 65)
Ambient functioning temperature °F (°C) 32 to 120 (0 to 49) 32 to 120 (0 to 49) 32 to 120 (0 to 49)
Ambient Relative Humidity [RH] % RH Minimum 30%, Maximum 90% Minimum 30%, Maximum 90% Minimum 30%, Maximum 90%
Surface area heat exchanger SQFT (m
2
) 22.0 (2.0) 27.2 (2.5) 43.0 (4.0)
Standard Listings & Approvals CSA, ASME, AHRI CSA, ASME, AHRI CSA, ASME, AHRI
Electrical Req. 120VAC/1PH/60Hz 2 FLA** 2.5 FLA** 2.5 FLA**
Noise rating dB 46 47 48
Weight (dry) lbs (kg) 198 (90) 220 (100) 242 (110)
Min. clearance to combustibles *** Inch (mm) 2” (50.8) 2” (50.8) 2” (50.8)
Dimension WxHxD
Inch
(mm)
23 31/32” x 61 9/16” x 21 21/32”
(609x1564x550)
23 31/32” x 61 9/16” x 21 21/32”
(609x1564x550)
23 31/32” x 61 9/16” x 21 21/32”
(609x1564x550)
AHRI certied ratings
Unit SSB255 SSB399 SSB512
Input MBH 255 399 511.8
Heating Capacity MBH 237.0 n/a n/a
Gross Output MBH n/a 386.0 495.0
AFUE % 96 n/a n/a
Combustion Efciency % n/a 97.6 95.4
Thermal efciency % n/a 96.9 96.8
Net rating MBH 206.0 336.0 430.0
CO
2 % 10.2 10.1 9.5
(*) With conversion.
(**) FLA (Full Load Amperage) - maximum current drawn by the boiler without pumps.
(***) The 2” minimum clearance is required for all sides of the boiler. The boiler may be installed on combustible (wood) oors excluding carpets.
See Fig. 9 for minimum clearance recommendation for serviceability.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus SSB512 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus SSB512 in the language / languages: English as an attachment in your email.

The manual is 9,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus SSB512

Buderus SSB512 Installation Guide - French - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info