Setting the system (programming parameters)
Logamatic EMS RC25 programming unit - Subject to technical modifications
30
7
Example:
If the clock in the programming unit is slow, e.g. by 2 seconds a day, enter +2 as the correction
value.
7.10 Thermal disinfection
1)
With this parameter P9 you can enable thermal disinfection. DHW will be heated once a week or
once a day to a temperature high enough to kill off pathogens (e.g. legionella bacteria). Parameter
P9 is only displayed if the programming unit is the sole programming unit (P1 = 0).
B Press pin button .
B Use rotary selector to select the required parameter (here: P9).
B Hold down pin button and simultaneously turn rotary
selector .
The corresponding value can be selected.
B Release pin button .
The setting is saved.
If you enable thermal disinfection (P9 = 1), then it will commence every Tuesday at 01:00 h and heat
the water to at least 70 °C. During the pasteurisation process the DHW circulation pump runs
constantly.
Parameter/function Input range Factory
setting
Other
information
P8/Time adjustment – 30 to +30 s/day 0 s/day
This parameter is not shown if the programming unit is installed as a remote control
(P1 unlike 0). The time and day are taken automatically from the RC30/RC35
programming unit where they can also be adjusted if necessary.
1) Function depends on the boiler used.
WARNING: Risk of scalding from hot water at the draw-off points!
During the thermal disinfection process the DHW can be heated to a temperature
above 60 °C.
B Do not open a hot water tap without mixing in cold water during or after the thermal
disinfection process.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus RC25 - Logamatic EMS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus RC25 - Logamatic EMS in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus RC25 - Logamatic EMS

Buderus RC25 - Logamatic EMS User Manual - English - 36 pages

Buderus RC25 - Logamatic EMS User Manual - German - 36 pages

Buderus RC25 - Logamatic EMS User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info