560499
27
Zoom out
Zoom in
Previous page
1/44
Next page
Logamatic EMS RC25 programming unit - Subject to technical modifications
27
Setting the system (programming parameters)
7
7.6 Type of pump
1)
Parameter P5 determines which pump transports heating water through the boiler:
with an internal boiler pump (1)
with a heating circuit pump (2)
B Press pin button .
B Use rotary selector to select the required parameter (here: P5).
B Hold down pin button and simultaneously turn rotary
selector .
The corresponding setting can now be selected.
B Release pin button .
The setting is saved.
1) This function is not available on boilers with UBA
Parameter/
function
Input range Factory
setting
Setting Explanation
P5/Type of
pump
0No pump 1
1 Internal boiler pump: in the event of a
DHW or heat demand from the boiler
control unit, the internal pump is switched
on simultaneously with the burner. After a
set pump run-on time, it stops again.
Generally select 1if a low loss header or a
3-way diverter valve is installed.
2 Heating circuit pump: the heating circuit
pump is switched by the boiler control
unit if the heating circuit demands heat.
This parameter is not shown if the programming unit is installed as a remote control
(P1 unlike 0). In this case set the type of pump at the RC30/RC35 programming unit.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus RC25 - Logamatic EMS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus RC25 - Logamatic EMS in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus RC25 - Logamatic EMS

Buderus RC25 - Logamatic EMS User Manual - English - 36 pages

Buderus RC25 - Logamatic EMS User Manual - German - 36 pages

Buderus RC25 - Logamatic EMS User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info