Setting the system (programming parameters)
7
7.3 Heating system: type of control and setback
If the programming unit is the sole programming unit in the system (P1 = 0), this parameter P2
determines the type of control for the heating system.
B Press pin button .
B Use rotary selector to select the required parameter
(here: /heating system).
B Hold down pin button and simultaneously turn rotary
selector .
The corresponding setting can now be selected.
B Release pin button .
The setting is saved.
Parameter/
function
Input range Factory
setting
Setting Type of
control
Type of
setback
Heating
system
Room temp.
-dependent
control
Explanation
P2/Heating
system
1 Room temp.
-dependent
control
Room
setback
Room flow Room flow (factory setting):
Room temperature control that responds
dynamically to deviations between the set
and actual room temperatures by
changing the flow temperature.
Select P2 = 1if you want changes in heat
output (e.g. due to the opening of
thermostatic valves in rooms other than
the reference room) to be compensated
for.
1
2 Room temp.
-dependent
control
Room
setback
Room output Room output:
Room temperature control that responds
dynamically to deviations between the set
and the actual room temperatures by
changing the boiler output. If there are
no major load fluctuations and only the
reference room is being controlled, select
P2 = 2. This means that changes in heat
output due to the opening of thermostatic
radiator valves in rooms other than the
reference room are compensated for only
very slowly. This room temperature
control is somewhat slower but also
leads to fewer burner starts than “Room
flow”.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus RC25 - Logamatic EMS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus RC25 - Logamatic EMS in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus RC25 - Logamatic EMS

Buderus RC25 - Logamatic EMS User Manual - English - 36 pages

Buderus RC25 - Logamatic EMS User Manual - German - 36 pages

Buderus RC25 - Logamatic EMS User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info