3 Gegevens betreffende het toestel
12
3.10 Technische gegevens
Eenheid WPT200I WPT200IS WPT250I WPT250IS
Vermogen - conform EN 16147, cyclus XL, luchttemperatuur 7 °C, waterverwarming van 10 °C naar 53 °C, Tref > 52,5 °C
Prestatiecoëfficiënt (COP) - - 2,81 2,83
Opwarmingstijd h - - 08:55 08:59
Warmteverlies in 24 h kWh/dag - - 0,75 0,84
Vermogen - conform EN 16147, cyclus L, luchttemperatuur 7 °C, waterverwarming van 10 °C naar 53 °C, Tref > 52,5 °C
Prestatiecoëfficiënt (COP) 2,75 2,6 - -
Opwarmingstijd h 7:55 7:47 - -
Warmteverlies in 24 h kWh/dag 0,61 0,83 - -
Vermogen - conform EN16147:2017, cyclus XL, luchttemperatuur 20 °C, waterverwarming van 10 °C naar 51 °C
Prestatiecoëfficiënt (COP) - - 3,45
Opwarmingstijd h - - 06:42
Warmteverlies in 24 h kWh/dia - - 0,60
Vermogen - conform EN16147:2017, cyclus L, luchttemperatuur 20 °C, waterverwarming van 10 °C naar 48 °C
Prestatiecoëfficiënt (COP) 3,48 - -
Opwarmingstijd h 05:29 - -
Warmteverlies in 24 h kWh/dia 0,55 - -
Luchtaanzuiging
Luchtcapaciteit (zonder/met 20 m leidingen) - ventilator-
stand "SP2"
m
3
/h 360/330
Luchtcapaciteit (zonder leidingen) - ventilatorstand "SP1" m
3
/h 290
Bedrijfstemperatuur °C +5 ... +35
Koelmiddelcircuit
Koelmiddel R134a g 270
Maximale druk MPa (bar) 2,7 (27)
Warm water
Capaciteit boiler l 200 193 247 240
Oppervlak warmtewisselaar (spiraalwarmtewisselaar) m
2
- 1 - 1
Continu vermogen van de spiraalwarmtewisselaar
1)
kW - 31.8 - 31.8
Maximale uitgangstemperatuur zonder/met elektrische bij-
verwarming
°C 60/70
Maximale bedrijfsdruk MPa (bar) 1 (10)
Elektrische gegevens
Stroomvoorziening V ~230 ( 10%)
Netfrequentie Hz 50
Stroomsterkte (zonder/met elektrische bijverwarming) A 2.6/11.3
Nominaal opgenomen vermogen max. (zonder bijverwar-
ming)
kW 0.6
Totaal verwarmingsvermogen van de elektrische bijverwar-
ming
kW 2.0
Nominaal opgenomen vermogen totaal maximaal
(met elektrische bijverwarming)
kW 2.6
Tabel 3 Technische gegevens
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logatherm WPT250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logatherm WPT250 in the language / languages: Dutch as an attachment in your email.

The manual is 4,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info