636472
29
Zoom out
Zoom in
Previous page
1/56
Next page
9
Montage du régulateur
Logano G315 – 6 720 817 943 (2016/04) 29
9.5 Câblage Hydrolevel HydroStat avec Beckett CF500 et brûleur CF800
Pour les applications nécessitant une conformité CSD-1, installer un disjoncteur de sécurité manuel entre L1 et la borne LMT, qui interrompt
l’alimentation électrique du brûleur.
Fig. 56 Schéma de connexion – Hydrolevel avec Becket CF500/CF800 (uniquement pour brûleur 120 V)
[1] Hydrolevel HydroStat
[2] Becket CF500/CF800
L1 Conducteur 1 câble réseau (conducteur de courant)
L2 Conducteur 2 câble réseau (neutre)
LMT Borne d’interrupteur valeur limite
MTR Borne de commande du moteur
S1 Soupape de mazout
S2 Soupape de mazout (à la pompe CleanCut)
TRANSFO Transformateur d’allumage
VLV Borne de commande de vanne
——— Câblage effectué en usine
------ Câblage effectué par l’installateur
L1 L2 C1 C2 B1 B2 I1 I2
Z
T
TV
L
B1 - L
B2 - N
N
120VAC
G
+
1 2
GRENZWERTE
DETEKTOR
A
K
D
A
A
C
F
120-V-ANSTEUERUNG (60Hz)
ÜBER ABGESICHERTEN SCHUTZSCHALTER,
BEREITSTELLUNG DURCH INSTALLATEUR
BEDIENER
A
TRAFO
S1
MOTOR
7505P
S2
AD
LMT
L1
L1
IGN
TR
TW
VLV
CAD
CAD
MTR
L2
L2
B
B
ERD-
ANSCHLUSS-
KLEMME
6 720 817 941-05.1T
DÉTECTEUR
BORNE DE RAC-
CORDEMENT À
LA TERRE
COMMANDE 120 V (60 Hz)
VIA INTERRUPTEUR DE PROTECTION AVEC FUSIBLE,
ÉTABLIE PAR L’INSTALLATEUR
VALEURS LIMITES UTILISATEUR
TRANSFO
MOTEUR
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logano G315 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logano G315 in the language / languages: French as an attachment in your email.

The manual is 3,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logano G315

Buderus Logano G315 Installation Guide - English - 56 pages

Buderus Logano G315 User Manual - English - 8 pages

Buderus Logano G315 User Manual - French - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info