560462
70
Zoom out
Zoom in
Previous page
1/76
Next page
Störungssuche und -beseitigung3
70 Serviceanleitung Logamax U112(K)/U114(K)/U122(K)/U124(K) • Ausgabe 12/2004
Änderungen aufgrund technischer Verbesserungen vorbehalten! W
3.1.46 Warmwassersensor prüfen bei
Logamax U122/124 (11/20/24/28 kW)
z Kabelstecker auseinanderziehen.
z Widerstandmessgerät anschließen.
z Gemessenen Wert mit den Werten der Tab. 4 ver-
gleichen. Stimmen die Werte (Toleranz ± 5%) über-
ein, ist der Warmwassersensor in Ordnung.
z Messgerät abnehmen.
z Ist der Warmwassersensor in Ordnung, Kabelstecker
zusammenstecken.
Abb. 97 Warmwassersensor prüfen
Tab. 4 Widerstandswerte des Warmwassersensors (Richt-
werte)
Temperatur [°C] Widerstand []
0 29490
5 23460
10 18790
15 15130
20 12260
25 10000
30 8194
35 6752
40 5593
45 4655
50 3893
55 3270
60 2760
65 2339
70 2000
75 1700
80 1458
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamax U112K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamax U112K in the language / languages: German as an attachment in your email.

The manual is 5,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info