Op de behoefte afgestemd onderhoud van de CV-installatie
Logamax plus GB152-24T - Wijzigingen op basis van technische verbeteringen voorbehouden!
74
11.3 Bij Logamax plus GB152-24 83S/170SR: platenwarmtewisselaar vervangen
V Bij onvoldoende warm tapwater dient u de platenwarm-
tewisselaar te vervangen.
V Zet de bedrijfsschakelaar in positie „0“ (Æ afb. 67,
pagina 65).
V Sluit de koudwaterleiding.
V CV-installatie aftappen.
V Open de warmwaterkraan.
V Sifon verwijderen (Æ afb. 75, pagina 73).
V Verwijder de schroeven (1 en 2) van de platenwarmte-
wisselaar.
V Platenwarmtewisselaar uitnemen.
V Plaats bij behoefte 4 nieuwe O-ringen.
V Monteer de platenwarmtewisselaar met beide schroe-
ven.
V Open de koudwaterleiding.
V Open de warmwaterkraan.
V Sluit de tapwaterkraan en schakel de CV-ketel weer in.
V Vul de CV-installatie (Æpar. 8.1, pagina 55).
Afb. 76 Schroeven van de platenwarmtewisselaar ver-
wijderen
11.4 Magnesiumanode controleren en
indien noodzakelijk vervangen
Over het algemeen raden we u aan om ten minste om de
twee jaar de magnesiumanode door een installateur te
laten controleren. Maak de gebruiker daarop attent.
Bij ongunstige wateromstandigheden (hard tot zeer hard
water) in combinatie met hoge temperatuurbelastingen
moet de boiler vaker gereinigd worden.
De magnesiumanode is een verbruiksanode, die door de
werking van de boiler oplost.
77
Voorzichtig: Schade aan de boiler door ge-
brekkig onderhoud
V Voer onderhoud ten minste om de twee
jaar uit.
V Verhelp gebreken onmiddellijk, om scha-
de te voorkomen!
Zorg ervoor dat het oppervlak van de magne-
siumstaaf niet in aanraking komt met olie of
vet. De anode moet steeds schoon blijven.
74


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamax plus GB152T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamax plus GB152T in the language / languages: Dutch as an attachment in your email.

The manual is 6,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info