Appendix16
17.2 Inspection report
z Please indicate the inspection activities that you
have carried out and enter the values measured.
Inspection activities page Date: ______ Date: ______ Date: ______
1. Test the general condition of the heating system
2. Carry out a visual inspection and test the functions of the
heating system
3. Test all gas and water conduits and fittings for:
– their tightness during operation
– visible corrosion
– signs of aging
– fill the condensate trap
45
44
29
4. Check the burner, the heat exchanger and the condensate trap
for pollution. First shut down the heating system
46
5. Check the burner and the ignition and ionization electrodes.
First shut down the heating system
46
6. Measure the ionization current 33 _______ µA _______ µA _______ µA
7. Measure the gas connection pressure (flow pressure) 30 _______ psi _______ psi _______ psi
8. Check the gas/air ratio 31 _____ inch W.C. _____ inch W.C. _____ inch W.C.
9. Carry out a gas tightness test in operating conditions 45
10. Measure the carbon monoxide content (CO) 45 _______ ppm _______ ppm _______ ppm
11. Check the water pressure of the heating system
– Inlet pressure of expansion tank (also see the
Installation Instructions for the expansion tank)
– Filling pressure
27
27
_______
_______ psi
_______ psi
12. Check the operation and safety of the air intake and flue pipe 30
13. Check that the thermostat is set in line with the needs
(see documents with thermostat)
36
14. Final check of inspection activities, note down the
measurement and test results
15. Confirm proper inspection
Company
stamp/signature
Company
stamp/signature
Company
stamp/signature
92


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamax plus GB142-45 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamax plus GB142-45 in the language / languages: English as an attachment in your email.

The manual is 4,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamax plus GB142-45

Buderus Logamax plus GB142-45 User Manual - German - 16 pages

Buderus Logamax plus GB142-45 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info