560472
3
Zoom out
Zoom in
Previous page
1/100
Next page
Contents
3
We reserve the right to make any changes due to technical modifications!
Installation and Servicing Instructions Logamax plus GB142-24/30/45/60 • Version 12/2004
Buderus Hydronic Systems • http://www.buderus.net
1 Safety and general instructions . . . . . . . . . . 5
1.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Hazard definitions . . . . . . . . . . . . . . . . . . . . . . 5
1.3 The following instructions must be observed . . 5
1.4 Observe these instructions for heating
system water . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.5 Tools, materials and additional equipment . . . 6
1.6 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2 Regulations and guidelines . . . . . . . . . . . . . 7
3 Product description . . . . . . . . . . . . . . . . . . . . 8
4 Dimensions and connections . . . . . . . . . . . . 9
5 Packaging and transportation . . . . . . . . . . 11
5.1 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . 11
5.2 Transporting the appliance . . . . . . . . . . . . . . 11
6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.1 Requirements for the installation room . . . . . 12
6.2 Fitting the appliance. . . . . . . . . . . . . . . . . . . . 12
6.3 Making the gas connection . . . . . . . . . . . . . . 13
6.4 Fitting the heating circuit supply and
return pipes . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.5 Combustion Air and Ventilation Openings . . . 17
6.6 Installation of the flue gas adapter
(included in the scope of delivery) . . . . . . . . . 18
6.7 Installation of the Exhaust and
Air Intake system. . . . . . . . . . . . . . . . . . . . . . 18
7 Connecting the condensate water drain . . 23
8 Electrical connections. . . . . . . . . . . . . . . . . 24
8.1 External connection board connections. . . . . 24
9 Start-up procedure. . . . . . . . . . . . . . . . . . . . 27
9.1 Testing for gas leaks . . . . . . . . . . . . . . . . . . . 28
9.2 Filling the appliance . . . . . . . . . . . . . . . . . . . . 28
9.3 Filling the condensate trap. . . . . . . . . . . . . . . 29
9.4 Venting the gas supply valve . . . . . . . . . . . . . 29
9.5 Checking the combustion air/flue gas
connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9.6 Checking the orrifices . . . . . . . . . . . . . . . . . . 30
9.7 Inlet gas pressure . . . . . . . . . . . . . . . . . . . . . 30
9.8 Checking and adjusting the gas/air ratio . . . . 31
9.9 Carrying out a tightness test in operating
conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
9.10 Measuring the carbon monoxide
content (CO) . . . . . . . . . . . . . . . . . . . . . . . . . 33
9.11 Function testing . . . . . . . . . . . . . . . . . . . . . . . 33
9.12 Measuring the ionization current . . . . . . . . . . 33
9.13 Installing the casing . . . . . . . . . . . . . . . . . . . . 35
9.14 Informing the owner, handing over the
technical documents . . . . . . . . . . . . . . . . . . . 35
10 BC10 basic controller . . . . . . . . . . . . . . . . . 36
10.1 Operating the BC10 basic controller . . . . . . . 36
10.1.1 Switching the heating system on and off . . . . 36
10.1.2 Displaying the operating conditions of
the burner and resetting the burner or
resetting burner faults . . . . . . . . . . . . . . . . . . 36
10.1.3 Displaying the heating system status
and/or faults. . . . . . . . . . . . . . . . . . . . . . . . . . 37
10.2 Carrying out additional tasks . . . . . . . . . . . . . 39
10.2.1 Carrying out a flue gas test . . . . . . . . . . . . . . 39
10.2.2 Selecting partial load operation
(e. g. during flue gas testing) . . . . . . . . . . . . . 39
10.2.3 Switching the heating system to
manual mode. . . . . . . . . . . . . . . . . . . . . . . . . 39
10.3 Configuring the appliance . . . . . . . . . . . . . . . 40
10.3.1 Adjusting the heating capacity. . . . . . . . . . . . 40
10.3.2 Setting the DHW temperature value . . . . . . . 41
10.3.3 Entering the heater water temperature . . . . . 41
10.3.4 Setting the pump post-purge period . . . . . . . 41
11 Shutting down the system . . . . . . . . . . . . . 43
11.1 Shut down the heating system using
the control unit. . . . . . . . . . . . . . . . . . . . . . . . 43
11.2 Shutting down the heating system
in the event of an emergency . . . . . . . . . . . . 43
12 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . 44
12.1 Preparing the appliance for inspection . . . . . 44
12.2 Visual inspection for general signs of
corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
12.3 Internal tightness testing . . . . . . . . . . . . . . . . 45
12.4 Measuring the ionization current . . . . . . . . . . 45
12.5 Measuring the inlet gas pressure . . . . . . . . . 45
12.6 Checking and adjusting the gas/air ratio . . . . 45
12.7 Carrying out a gas tightness test in
operating conditions . . . . . . . . . . . . . . . . . . . 45
12.8 Measuring the carbon monoxide
content (CO) . . . . . . . . . . . . . . . . . . . . . . . . . 45
12.9 Carrying out a pressure test of the
heating system . . . . . . . . . . . . . . . . . . . . . . . 45
12.10 Checking the functioning and the safety
of the air intake and flue gas conduit. . . . . . . 45
12.11 Checking venting systems. . . . . . . . . . . . . . . 45
13 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . 46
13.1 Cleaning the heat exchanger, burner
and condensate trap . . . . . . . . . . . . . . . . . . . 46
13.2 Checking and adjusting the gas/air-ratio . . . . 48
14 Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
14.1 Checking the UBA3 fuse;
replace if necessary . . . . . . . . . . . . . . . . . . . 49
14.2 External connection board fuse . . . . . . . . . . . 49
14.3 Checking the fan unit; 120 VAC control . . . . 50
14.4 Checking the fan unit;
Supply cord (120 VAC) . . . . . . . . . . . . . . . . . 51
14.5 Checking the fan unit; Tacho cable . . . . . . . . 52
14.6 Replacing the fan unit . . . . . . . . . . . . . . . . . . 52
14.7 Checking the supply/return/safety/
hot-water temperature sensors . . . . . . . . . . . 53
14.8 Replacing the supply/return/safety sensors . 54
14.9 Checking the supply/return/
safety sensors cable . . . . . . . . . . . . . . . . . . . 55
14.10 Checking the hot surface ignitor; Control . . . 56
14.11 Checking the hot surface ignitor; resistance . 57
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamax plus GB142-24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamax plus GB142-24 in the language / languages: English as an attachment in your email.

The manual is 4,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamax plus GB142-24

Buderus Logamax plus GB142-24 User Manual - German - 16 pages

Buderus Logamax plus GB142-24 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info