Mesures7
Logamax plus GB022-24K - Sous réserve de modifications techniques.
54
Section 115
z Régler le multimètre sur « Mesure de la résistance ».
z Détacher les câbles des sondes de température ECS [3]
et [4] du tableau de commande.
z Mesurer la résistance, les courts-circuits et ruptures
éventuels du câble de la sonde de température ECS
(Æ Paragraphe 113).
z Monter le câble de la sonde de température ECS sur le
tableau de commande ([3] et [4]).
Section 116
z Monter le câble de la sonde correspondante de
température ECS ou de température d'écoulement.
z Monter le tableau de commande et mettre la chaudière
en marche (Æ Paragraphe 55, 56 ou 51).
1
2
3
4
5
6
7
Room Controller
Hot water tank sensor
24 VAC
3-way valve
Room Controller
Hot water tank sensor
24 VAC
3-way valve
8
9
Section 117 Remplacer la sonde de départ et la
sonde de température de sécurité
z Mettre la chaudière hors service, vidanger l'installation et
retirer la fiche de la sonde correspondante
(Æ Paragraphe 42, 43, 46, 44, 46, 48 ou 49).
Section 118
AATTENTION !
De l'eau résiduelle coule lors du démontage de la
sonde. Tenir un seau et un chiffon à disposition.
z Détacher la fiche de la sonde de température de
sécurité [1].
z Retirer le ressort de sécurité de la sonde de température
de sécurité dans le sens de la flèche [2].
z Démonter la sonde de température de sécurité [3].
Section 119
AATTENTION !
De l'eau résiduelle coule lors du démontage de la
sonde. Tenir un seau et un chiffon à disposition.
z Retirer le ressort de sécurité de la sonde de départ en le
déplaçant dans le sens de la flèche.
z Retirer la sonde de départ.
1
3
2
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamax plus GB022-24K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamax plus GB022-24K in the language / languages: French as an attachment in your email.

The manual is 5,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamax plus GB022-24K

Buderus Logamax plus GB022-24K Installation Guide - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info